Connect the Cluster Cables
The cluster interface card provides three redundant links that enable two
controllers to communicate with each other. The cluster I/O ports consist of two
serial links (0,1) and an Ethernet link. Cluster cabling must be done before
powering on either controller, and all three links must be established before
configuration can proceed.
-
Locate the 3-port cluster interface card in PCIe slot 3.
-
Identify the three cluster cables provided for your engineered system.
These are straight-through Cat-5-or-better Ethernet cables, and are typically
7 ft (2.15 m) in length.
-
Connect the cluster serial ports of each controller to form a crossover
pattern:
-
Connect one Ethernet cable between serial port 0 of one controller and
serial port 1 of the other controller.
-
Connect another Ethernet cable between serial port 1 of one controller
and serial port 0 of the other controller.
The cables between the serial ports form a crossover pattern.
-
Connect one Ethernet cable between the Ethernet ports of each
controller.