The program description deals with the following:
The data of device type Pr60-60 fiscal printer can be updated, i.e. programmed, changed or cleared, with this program. Data which has already been stored can be displayed for information.
In addition to the specific printer parameters the interface and link to a processing unit have to be defined.
Note:
Before this printer can be operated interface
card IMC 70 must be installed to allow for connection.
Documentation IMC 70 contains further details on installation and configuration of the IMC 70 interface board.
Additional settings are necessary in the MICROS Retail OSCAR POS program if a fiscal printer is to be used. The documentation FISCALIZATION provides more details.
The following description deals with all available options for update of this basic data.
As with nearly all other programs the following also applies here:
Path and name of DLL file for the device driver for IMC devices
The standard is that this data is stored in MICROS Retail OSCAR POS directory ..\bin\. The entry in this field should read ../bin/imc1_87.dll.
Entry range permitted: alphanumeric max. 18 pos.
Enter the factory no. of the fiscal printer in this field.
Entry range permitted: alphanumeric max. 15 pos.
Enter the fiscal ID no. in this field.
Entry range permitted: alphanumeric max. 12 pos.
Enter the fiscal no. in this field.
Entry range permitted: alphanumeric max. 20 pos.
Entry range permitted: alphanumeric max. 20 pos.
Field with firmly defined selection options
Select one of the offered debug levels by clicking onto this field and with a second click confirming the selection.
The system offers the following debug levels:
Note:
Only select a value higher than "0" for
the debug level if a protocol of communications is required for error analysis.
Entry range permitted: numeric 1 - 9 (default = 0)
Enter the number of decimal places.
Entry range permitted: numeric 1 - 99 (default = 24)
Field with firmly defined selection options
Select one of the offered operating modes for the customer display by clicking onto this field and with a second click confirming the selection.
The system offers the following settings:
Field with firmly defined selection options
Select one of the offered operating modes for the operator display by clicking onto this field and with a second click confirming the selection.
The system offers the following settings:
Entry range permitted: numeric 1 - 9 (default = 1)
Default = 1000 milliseconds
Poll timeout when drawer is open.
Default = 200 milliseconds
Poll timeout when drawer is closed.
Switch active: An operator
display is connected
Switch deactivated: No operator display is connected.
Switch active:
Switch deactivated:
Switch active:
Switch deactivated:
Switch active:
Switch deactivated: