Drink dispenser WMF Hogatron (E-Prot)

The program description deals with the following:

Note:
Please note that this drinks dispenser can also commmunicate with the MICROS Retail OSCAR POS application via the ADS protocol. In such a case, the dispenser type WMF Hogatron (E-Prot) should be set in update program Device.


Remarks on program function

Data for connection of a drinks dispenser, type WMF-Hogatron (E-Prot), can be updated, i.e. programmed, changed or cleared, with this program. Data which has already been stored can also be displayed for information.

The interface and link to a processing unit must be defined and the device-specific operating mode of the drinks dispenser set.

Drinks dispensers can be used in two different modes: self service and supervised dispensing. (credit debit).

Click on the graphic for further help with programming Drink dispenser .


Remarks on data fields

The following description deals with all available options for update of this basic data.

As with nearly all other programs the following also applies here:


Debug

Field with firmly defined selection options

Select one of the offered debug levels by clicking on this field and with a second click confirming the selection.

The system offers the following debug levels:

Note:
Only select a value higher than "0" for the debug level if a protocol for communciation of the drinks dispenser is required for error analysis. The details are shown in file "errlog" in directory work of the appropriate system unit.


Baudrate

Field with firmly defined selection options

Select one of the offered baud rates by clicking on this field and with a second click confirming the selection.

The system offers the following baud rates:

Please ensure that the baud rate matches up with the setting for the connected drinks dispenser.


Poll timeout

Default =1000 milliseconds


Request timeout

Default = 3000 milliseconds


1st byte timeout

Default = 600 milliseconds


I.Byte timeout

Default = 200 milliseconds


Usage

Default = 1


ISB PLU table

Switch active: The PLU nos. are converted using a table in the drinks dispenser
Switch deactivated: The PLU nos. are converted using the drinks dispenser table in the MICROS Retail OSCAR POS application


Crc on

Switch active: E-protocol with check sum
Switch deactivated: E-protocol without check sum


ISB com 1

Switch active: Interface 1 of the ISB box (intelligent interface box) is used
Switch deactivated: Interface 1 of the ISB box is not used

If this interface is used, the items will have to be converted to numbers 1001 to 1999 of the device article (see upate program Device item group).


ISB com 2

Switch active: Interface 2 of the ISB box (intelligent interface box) is used
Switch deactivated: Interface 2 of the ISB box is not used

If this interface is used, the items will have to be converted to numbers 2001 to 2999 of the device article (see upate program Device item group).


ISB com 3

Switch active: Interface 3 of the ISB box (intelligent interface box) is used
Switch deactivated: Interface 3 of the ISB box is not used

If this interface is used, the items will have to be converted to numbers 3001 to 3999 of the device article (see upate program Device item group).


ISB com 4

Switch active: Interface 4 of the ISB box (intelligent interface box) is used
Switch deactivated: Interface 4 of the ISB box is not used

If this interface is used, the items will have to be converted to numbers 4001 to 4999 of the device article (see upate program Device item group).


ISB com 5

Switch active: Interface 5 of the ISB box (intelligent interface box) is used
Switch deactivated: Interface 5 of the ISB box is not used

If this interface is used, the items will have to be converted to numbers 5001 to 5999 of the device article (see upate program Device item group).


ISB com 6

Switch active: Interface 6 of the ISB box (intelligent interface box) is used
Switch deactivated: Interface 6 of the ISB box is not used

If this interface is used, the items will have to be converted to numbers 6001 to 6999 of the device article (see upate program Device item group).


ISB com 7

Switch active: Interface 7 of the ISB box (intelligent interface box) is used
Switch deactivated: Interface 7 of the ISB box is not used

If this interface is used, the items will have to be converted to numbers 7001 to 7999 of the device article (see upate program Device item group).


ISB com 8

Switch active: Interface 8 of the ISB box (intelligent interface box) is used
Switch deactivated: Interface 8 of the ISB box is not used

If this interface is used, the items will have to be converted to numbers 8001 to 8999 of the device article (see upate program Device item group).