To correctly reset the date and time after replacing a battery, you must prevent the host from automatically powering on, and also disable any NTP server connections. Before you remove power from the server, perform these steps.
-> show /SP/policy HOST_AUTO_POWER_ON
/SP/policy
Properties:
HOST_AUTO_POWER_ON = enabled
-> set /SP/policy HOST_AUTO_POWER_ON=disabled
-> show /SP/clock usentpserver
/SP/clock
Properties:
usentpserver = enabled
-> set /SP/clock usentpserver=disabled
Replacing the battery is a cold-service procedure. The server must be completely powered down before performing this procedure.
The following example sets the date to August 22, 2016, and the timezone to EDT.
-> set /SP/clock datetime=0812213202016 timezone=EDT
Set 'datetime' to '0812213202016'
Set 'timezone' to 'PEDT'
-> show -d properties /SP/clock
/SP/clock
Properties:
datetime = Mon Aug 22 13:20:16 2016
timezone = EDT (EST5EDT)
uptime = 2 days, 19:56:49
usentpserver = disabled
-> set /SP/policy HOST_AUTO_POWER_ON=enabled
-> set /SP/clock usentpserver=enabled
Check the status of the system battery.
-> show /SYS/MB/BAT