17 Servicing Other Cables (FRU)
The following section describes how to service the front indicator module (FIM), temperature sensor, and disk backplane data and power cables. These cables are field-replaceable units (FRUs). For more information about FRUs, see Illustrated Parts Breakdown and Field-Replaceable Units.
Caution:
The FIM, temperature sensor, and disk backplane data and power cables must be removed and replaced only by authorized Oracle Service personnel.Caution:
Ensure that all power is removed from the server before removing or installing these cables. You must disconnect the power cables before performing this procedure.Caution:
These procedures require that you handle components that are sensitive to electrostatic discharge. This sensitivity can cause the component to fail. To avoid damage, ensure that you follow electrostatic discharge safety measures and antistatic practices. See Electrostatic Discharge Safety.This section covers the following procedures:
Remove the FIM, Temperature Sensor, and Disk Backplane Data and Power Cables
-
Prepare the server for service.
-
Remove the disk backplane power cable.
-
Remove the temperature sensor cable.
-
Remove the FIM cable.
-
Remove the disk backplane data cable.
- Eject the disk backplane data cable from the disk backplane by opening both side latches on the connector [7].
- Eject the disk backplane data cable from the motherboard by opening both side latches on the connector [8].
Install the FIM, Temperature Sensor, and Disk Backplane Data and Power Cables
-
Install the disk backplane data cable.
-
Install the FIM cable.
-
Install the temperature sensor cable.
-
Install the disk backplane power cable.
- Connect the disk backplane power cable to the disk backplane by plugging the cable connector into the disk backplane connector [2].
- Connect the disk backplane power cable to the motherboard by plugging the cable connector into the motherboard connector [1].
-
Return the server to operation.