About This Documentation (PDF and HTML)
SAS Device Access to the Chassis SAS-2 Domain
Host Access to Storage Module Resources Using the Sun Blade Zone Manager
How to Assign Storage to Hosts Using the CMM ILOM Web Interface
How to Assign Storage to Hosts Using the CMM ILOM CLI
Overview of Storage Module Management
Management Options Using the CMM ILOM
Management Options Using the Sun Storage 6Gb SAS REM RAID HBA (SGX-SAS6-R-REM-Z)
Management Options Using the Sun Storage 6Gb SAS REM HBA (SGX-SAS6-REM-Z)
Performing Maintenance and Hot Plug Actions
Preparing for Hot Plug Actions
Recovering Zoning Configurations
Upgrading Storage Module Firmware
Importing Existing Virtual Drives to a Replacement REM
Replacing a REM on a SPARC System
Replacing a REM on an x86 System
Storage Module Sensors and Indicators
Displaying Sensor and Indicator Information Using the CMM ILOM Web Interface
Displaying Sensor and Indicator Information Using the CMM ILOM CLI
Viewing the CMM ILOM Event Log
Sun Blade Zone Manager Not Ready
Missing SAS-2 Components Error
A newly inserted NEM in the chassis does not appear in the Sun Blade Zone Manager web interface, or is not present in the CLI under /STORAGE/sas_zoning.
What to look for:
The following table provides examples of how the web interface and CLI might look like if you installed a second NEM for dual path support and wanted to check that the second NEM was seen by the Sun Blade Zone Manager.
|
The above example does not list the second NEM, even though it was installed.
Things to check:
Check the CMM ILOM event log (see Viewing the CMM ILOM Event Log) for messages relating to the NEM.
Actions to perform:
If no messages about the newly installed NEM have been logged, wait 5 minutes for the CMM to properly discover and integrate the new NEM into the SAS-2 fabric. Use the CMM ILOM web interface or CLI to run the Sun Blade Zone Manager again.
Either press the NEM Attention button, or perform a return_to_service action.
If you see “/CH/NEMx failed to join SAS2 fabric" (where x is the slot number of the NEM), do the following:
Pull out the failed NEM.
Wait until the removal is processed.
You will see that the removal is processed when a "Hot removal of /CH/NEMx" message (where x is the slot number of the NEM) is logged.
Once the removal message is seen, it is safe to reinsert the NEM.
If you see "/CH/NEMx successfully added to SAS2 fabric" (where x is the slot number of the NEM), this means that the NEM is now ready to be configured by the Sun Blade Zone Manager. Use the CMM ILOM web interface or CLI to run the Sun Blade Zone Manager again.