LEDs and Logs Incorrectly Indicate That CMOD Has Failed (CR 7033674)

On rare occasions, the system incorrectly indicates that a CMOD has failed. The following messages appear:

  • An FMA fault of fault.chassis.device.fail for /SYS/BLx.

  • An event entry of /SYS/BLx/ERR : Predictive Failure Asserted in the Oracle ILOM log.

  • The system Service Required LED, and the Service Required LED on the CMOD light.

Workaround

If the CMOD appears to be functioning normally, you can fix the problem using the following procedure.

  1. To clear the fault messages, perform one of the following:

    • From the Oracle ILOM command line, enter the command:

      set /SYS/BLx clear_fault_action=true

      where x is the CMOD number.

    • From the Oracle ILOM GUI:

      • Click the System Information > Components tab.

        The Component Management page appears.

      • In the Component Management page, click the radio button next to the faulted component, then select Clear Faults.

  2. After 10 minutes, reset the SP using one of the following methods:

    • From the CLI, enter the reset /SP command, or

    • From the GUI.

      • Select Maintenance > Reset SP.