Environmental Requirements
The
HBA environmental requirements are listed in Figure 5, Table 5, HBA Environmental Requirements .
Table 5 HBA Environmental Requirements
|
|
|
|
0˚ to 55˚C, non-condensing |
-20˚C to 85˚C, non-condensing |
|
10% to 90% RH, non-condensing, 22˚C
max wet bulb |
5% to 95% RH, non-condensing, 22˚C
max wet bulb |
|
3200 m |
12,200 m |
|
0.25 g in all axes, 5-500 Hz sine |
1.2 g in all axes, 5-500 Hz sine |
|
5.5 g, 11 ms half-sine |
33 g, 11 ms half-sine |
|