Install the Front Indicator Module


Caution  -  The front indicator module should be installed only by authorized Oracle Services personnel.


  1. Attach an antistatic wrist strap to your wrist, and then to a metal area on the chassis.

    See Take Antistatic Measures

  2. Unpack the replacement FIM and place it on an antistatic mat.
  3. Connect the FIM cable to the replacement FIM assembly.

    For reference, use the illustration provided in Remove the Front Indicator Module.

  4. Carefully lower the FIM assembly into the chassis, position it over the Phillips screw in the server chassis, and slide it forward so all the LEDs, USB connectors, and Power On button fit into place on the server front panel [2].
  5. Tighten the Phillips screw to secure the FIM assembly to the server chassis [2].
  6. Position the storage drive cage cover over the server storage drive cage so that it over hangs the front of the disk drive cage by about 1/4 inch.
  7. Install the six Phillips screws to secure the cover to the server [1].

    There are three Phillips screws on each side of the storage drive cage.

  8. Close the server fan door.
  9. Return the server to operation.
    1. Return the server to the normal rack position.

      See Return the Server to the Normal Rack Position.

    2. Reconnect the data cables to the server and reconnect the power cords to the server power supplies.

      See Reconnect Data Cables and Power Cords.

    3. Power on the server.

      See Power On the Server.

      Verify that the Power/OK status indicator is steady on.