StorageTek Dual 8 Gb FC Dual GbE ExpressModule HBA From QLogic Installation Guide

For HBA Models SG-PCIEFCGBE-Q8-Z, SG-XPCIEFCGBE-Q8-Z, SG-PCIEFCGBE-Q8-N, and SG-XPCIEFCGBE-Q8-N

Oracle Technology Network
Library
PDF
Print View
Feedback
search filter icon
search icon

Document Information

Using This Documentation

Chapter 1 HBA Overview

Chapter 2 Hardware Installation and Removal

Observing ESD and Handling Precautions

Installing the Hardware

To Install the HBA

Connecting the Cables to the HBA

To Connect the Cables to the HBA

To Power On the HBA

LED Descriptions and Status

LED and Switch Locations

Fibre Channel LED Indicator Status

Ethernet LED Indicator Status

Power and Attention Switch LED Scheme

Configuring the HBA for Hot-Plug Operation

To Configure the HBA for Hot-Plug Operation

Testing the Installation

To Test the Installation for the Oracle Solaris OS

Testing the Installation for the Windows OS

Testing the Installation for the VMware Technology

Removing the Hardware

To Prepare the HBA for Removal Using the HBA Attention Button

To Prepare the HBA for Hot-Plug Removal Using the Oracle Solaris OS

To Remove the HBA

Chapter 3 Software Installation

Chapter 4 Known Issues

To Install the HBA

  1. Attach an ESD wrist strap (see Observing ESD and Handling Precautions).
  2. Refer to your system installation or service manual to determine an appropriate ExpressModule slot in which to install the HBA.
  3. Press down the plastic tab to release the ExpressModule latch and pull the lever out until it is nearly perpendicular with the ExpressModule front panel.

    Figure 2-1  Releasing the HBA Latch


    image:The figure shows how to release the HBA latch
  4. Insert the HBA into its slot, being careful that the tooth on the bottom of the lever does not come in contact with the chassis sheet metal during insertion.
  5. When the HBA is inserted nearly all the way into its slot, push the lever back into its fully closed position, allowing the lever tooth to insert the HBA fully into place.