JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Blade X6275 M2 Server Module Product Notes
search filter icon
search icon

Document Information

Using This Documentation

Product Information Web Site

Related Books

About This Documentation (PDF and HTML)

Documentation Comments

Contributors

Change History

Overview of the Sun Blade X6275 M2 Server Module Product Notes

System Software Release Features

Firmware Release History

Supported Hardware

Supported Operating Systems

Integrated Lights Out Manager (ILOM)

Additional Software

Hardware, Firmware, and BIOS Issues

Hardware, Firmware, and BIOS Current Issues

Care and Handling of Server Modules with FMods

Setup and Power-On Recommendations for the Sun Blade 6000 Modular System Chassis

Setup and Power-on Recommendations With an Empty System Chassis

Setup and Power-on Recommendations With a Preconfigured System Chassis

PCIe Link Speed Reduced With BIOS 10.2.6.0 (6994690)

PC-Check 6.27s Does Not Recognize Mellanox 10GbE Chip (6992284)

Performance Degradation When BIOS Hardware Prefetcher is Enabled

Identifying a Node's Onboard Device Versus a Node's PCIe EM (7072665)

Management and ILOM Issues

Management and ILOM Current Issues

Linux Issues

Linux Current Issues

Oracle Solaris Issues

Oracle Solaris Current Issues

Windows Issues

Windows Current Issues

Documentation Issues

Documentation Current Issues

Setup and Power-on Recommendations With an Empty System Chassis

  1. Before installing server blades, make sure that all of the chassis components are installed (power supplies, fans, NEMs, EMs, etc.).
  2. Connect required I/O cables for the chassis (Ethernet, etc.).
  3. Install and fully seat Blade 0.
  4. Attach all AC power cables from the system chassis power interface module to a power source.

    The chassis automatically applies main power to all blades in the chassis after power is provided to the power supplies. Ensure that all power LEDs are lit.

  5. Set up your CMM IP address with a DHCP/Static address.
  6. Verify the CMM network and check/setup the blade SP network.
  7. Install other blades with a 30 second interval between each blade insertion.

    For example, after Blade 0 has been powered, wait 30 seconds. Then install and fully seat Blade 1 and wait 30 seconds for them to power on.

    Then install and fully install Blade 2 and wait 30 seconds for them to power-on. Repeat the process until all blades are installed.

  8. Verify that no fault (amber) LEDs are lit on blade or chassis components (CMM, PSU, blades, etc.).

    If fault LEDs are lit, follow the troubleshooting procedures described in the Sun Blade X6275 M2 Server Module Service Manual and refer to the Product Notes for any known issues.