Environmental
Specifications
The Oracle Flash Accelerator F160 PCIe Card operates and is stored in an environment defined
by the parameters and specifications in the following table:
|
|
Operating temperature
|
0 to 55° C with specified airflow
|
Non-operating temperature
|
Storage and transit environment: –55° C to 95° C (dry bulb)
|
Temperature monitoring
|
|
Dry bulb temperature
|
Maximum dry bulb temperature shall be derated by 3.3° C per 1000 m above 500 m
|
Altitude (Simulated)
|
-
Operating: -1,000 to 10,000 ft
-
Non-Operating: -1,000 to 40,000 ft
|
Relative humidity range
|
-
Operational environment: 8% to 80% noncondensing
-
Storage and transit environment: 5% to 95% noncondensing
-
Non-operating: -20° C to 75° C noncondensing
|
Thermal sensors
|
|
Airflow requirement
|
More than 300 LFM (linear feet/minute) at 55° C with airflow
towards IO bracket
|
|
Note -
For specific site planning guidelines and best practices, refer to the server documentation
and product notes for your server. Refer to the system site planning guide, if available.