ok probe-scsi-all /pci@400/pci@1/pci@0/pci@LSI,sas@0 FCode Version 1.00.54, MPT Version 2.00, Firmware Version 5.00.17.00 Target 9 Unit 0 Disk SEAGATE ST9300003SSUN3006 0B70 585937500 Blocks, 300 GB SASDeviceName 5000c50033438dbb SASAddress 5000c50033438db9 PhyNum 0 Target b Unit 0 Dusj SEAGATE ST930003SSUN300G 0468 585937500 Blocks, 300 GB SASDeviceName 5000c50005c15803 SASAddress 5000c50005c15801 PhyNum 1 Target c Unit 0 Elcl Serv device SUN NEM Hydra II SOL 0308 SASAddress 5080020000bb193d PhyNum 24 /pci@400/pci@1/pci@0/pci@0/pci@0/usb@0,2/hub@3/storage@2 Unit 0 Removable Read Only device AMI Virtual CDROM 1.00
LSI,sas@0 – Disk controller, followed by its associated target drives with their Target IDs. If the server has more than one disk controller, the target drives associated with each controller are listed following that controller's information.
SASDeviceName – WWN that Oracle Solaris recognizes.
SASAddress – WWN that OpenBoot references.
PhyNum – Physical slot that the drive occupies (the value 0 indicates a drive in HDD slot 0).
For the example output, you can construct an Oracle Solaris device name for the drive in slot 0, indicated with PhyNum 0, as follows:
cn = c0
n is the SAS disk controller number.
tWWN = t5000c50033438dbb
WWN is the SASDeviceName value.
dn = d0
n is 0 for all embedded SCSI devices.
The completed logical device name is c0t5000c50033438dbbd0.