Go to main content

SPARC T7-2 Server Installation Guide

Exit Print View

Updated: July 2017
 
 

Electrical Specifications

Description
Value
Notes
Voltage
200 to 240 VAC
Frequency
50 to 60 Hz
Maximum operating input current at 200 VAC (per cord)

The maximum operating input current values are based on P / (V *0.95), where P = max. operating input power, V= input voltage. Example: 1060W / (220 * 0.95) = 5.1A You can use this equation to calculate your maximum operating current at your input voltage.

10.75A

Actual amperage draw may exceed rating by no more than 10%.

Maximum operating input power at 200 VAC
2475W
Maximum standby power
45W
Idle input power (maximum configuration)

Maximum server configuration specification under nominal temperature and voltage conditions (two 4.133-GHz M7 processors with thirty two 32-GB DDR4 DIMMs, 6 SSD drives, and 8 PCIe cards).

1150W
Idle input power (minimum configuration)

Minimum server configuration specification under nominal temperature and voltage conditions (two 4.133-GHz M7 processors with sixteen 16-GB DDR4 DIMMs, no drives, and no PCIe cards).

945W
Peak AC power (maximum configuration)
2215W
Conforms to SpecJBB.
Peak AC power (minimum configuration)
1725W
Conforms to SpecJBB.
Maximum heat dissipation
8447 BTU/hr
8912 KJ/hr

For information on power specifications, use the power calculator at:

http://www.oracle.com/us/products/servers-storage/sun-power-calculators