Install the Module

  1. Identify the prerequisite and subsequent installation tasks that you must perform in conjunction with this task.

    See Installation Task Overview.

  2. If the rack rear door is installed, open it.
  3. Remove the module from its antistatic packaging.
  4. Squeeze the top and bottom of the release lever, and move the release lever to the fully open position.
    image:Illustration shows opening the release lever.
  5. Align the module to the slot where you are installing it.

    The LEDs and data cable receptacles face you, and the release lever is to the lower right.

  6. Slide the module into the chassis until the release lever begins to rise.
  7. When the module is almost completely seated in the slot and the release lever begins to rise, press down slightly on the top of the module to ensure that the notch at the end of the release lever catches onto the groove in the slot entrance in order to secure the module.

    Note -  Ensure the handle appears in the fully locked position as in the illustration when fully engaged.

    image:Illustration shows installing and securing the module into the                             slot.
  8. Verify that the green OK LED lights.
  9. Repeat Step 3 to Step 8 to install the remaining modules.
  10. Connect the data cables to the module.

    See Connect Cables and Transceivers.