ok probe-scsi-all /pci@302/pci@2/pci@0/pci@14/LSI,sas@0 FCode Version 1.00.65, MPT Version 2.05, Firmware Version 9.00.00.00 Target 9 Unit 0 Disk HGST H101860SFSUN600G A3T0 1172123568 Blocks, 600 GB SASDeviceName 5000cca02f0256b8 SASAddress 5000cca02f0256b9 PhyNum 0 Target a Unit 0 Disk HGST H101860SFSUN600G A3T0 1172123568 Blocks, 600 GB SASDeviceName 5000cca02f02564c SASAddress 5000cca02f02564d PhyNum 1 Target b Unit 0 Disk HGST H101860SFSUN600G A770 1172123568 Blocks, 600 GB SASDeviceName 5000cca02f1390f4 SASAddress 5000cca02f1390f5 PhyNum 2 Target c Unit 0 Disk HGST H101860SFSUN600G A770 1172123568 Blocks, 600 GB SASDeviceName 5000cca02f1376d8 SASAddress 5000cca02f1376d9 PhyNum 3 Target d Unit 0 Disk HGST H101860SFSUN600G A3T0 1172123568 Blocks, 600 GB SASDeviceName 5000cca02f027838 SASAddress 5000cca02f027839 PhyNum 4 Target e Unit 0 Disk HGST H101860SFSUN600G A3T0 1172123568 Blocks, 600 GB SASDeviceName 5000cca02f02e798 SASAddress 5000cca02f02e799 PhyNum 5 Target f Unit 0 Disk HGST H101860SFSUN600G A3T0 1172123568 Blocks, 600 GB SASDeviceName 5000cca02f02b138 SASAddress 5000cca02f02b139 PhyNum 6 Target 10 Unit 0 Disk HGST H101860SFSUN600G A3T0 1172123568 Blocks, 600 GB SASDeviceName 5000cca02f028fd0 SASAddress 5000cca02f028fd1 PhyNum 7 /pci@300/pci@1/pci@0/pci@2/usb@0/storage@1 Unit 0 Disk smiMICRON eUSB DISK 1112 /pci@300/pci@1/pci@0/pci@2/usb@0/hub@2/storage@1 Unit 0 Removable Read Only device SUNRemote ISO CDROM1.01
LSI,sas@0 – ディスクコントローラ (この例では REM)。サーバーに複数のディスクコントローラが搭載されている場合は、各コントローラの情報のあとに、そのコントローラに関連付けられたターゲットドライブが一覧表示されます。
SASDeviceName – Oracle Solaris が認識する WWN。
SASAddress – OpenBoot が参照する WWN。
PhyNum – ドライブが搭載される物理スロット (値 0 は HDD スロット 0 のドライブを示す)。
この例では、次のような名前を作成してスロット 0 のドライブを示しています。
cn = c0
ここで、n は SAS のコントローラ番号です。
tWWN = t5000cca02f0256b8
ここで、WWN は SASDeviceName 値です。
dn = d0
ここで、すべての内蔵 SCSI デバイスを示す場合、n は 0 です。
完成した論理デバイス名は c0t5000cca02f0256b8d0 です。