Electrical Specifications

Description
Value
Notes
Voltage
200 to 240 VAC
Frequency
50 to 60 Hz
Maximum operating input current at 200 VAC (per cord)

The maximum operating input current values are based on P / (V *0.95), where P = max. operating input power, V= input voltage. Example: 1060W / (220 * 0.95) = 5.1A You can use this equation to calculate your maximum operating current at your input voltage.

10A

Actual amperage draw may exceed rating by no more than 10%.

Maximum operating input power at 200 VAC
3080W
Maximum standby power
45W
Maximum heat dissipation
10512 BTU/hr
11090 KJ/hr

For information on power specifications, use the power calculator at:

http://www.oracle.com/us/products/servers-storage/sun-power-calculators