Environmental Specifications

Oracle Flash Accelerator F640 PCIe Card operates and is stored in an environment defined by the parameters and specifications listed in the following table.

Specification
Value
Operating temperature
0 to 55°C with specified airflow
Non-operating temperature
Storage and transit environment: –55°C to 95°C (dry bulb)
Temperature monitoring
Thermal sensors
Dry bulb temperature
Maximum dry bulb temperature is derated by 3.3°C per 1000 m above 500 m
Altitude (Simulated)
  • Operating: -1,000 to 10,000 ft

  • Non-operating: -1,000 to 40,000 ft

Relative humidity range
  • Operational environment: 8% to 80% noncondensing

  • Storage and transit environment: 5% to 95% noncondensing

  • Non-operating: -20°C to 75°C noncondensing

Airflow requirement
More than 400 LFM (linear feet/minute) at 55°C, with airflow towards IO bracket

Note -  For specific site planning guidelines and best practices, refer to the server documentation and product notes for your server. Refer to the system site planning guide, if available.