Usage Information
Oracle Flash Accelerator F640 PCIe Card v2 operates and is stored in an environment defined by
the parameters and specifications listed in the following table.
|
|
Operating temperature
|
0 to 55°C with specified airflow
|
Non-operating temperature
|
Storage and transit environment: –55°C to 95°C (dry
bulb)
|
Temperature monitoring
|
Temperature monitoring in-band and by way of SMBUS
|
Thermal sensors
|
|
Dry bulb temperature
|
Maximum dry bulb temperature is derated by 3.3°C per 1000 m
above 500 m
|
Altitude (Simulated)
|
-
Operating: -1,000 to 10,000 ft
-
Non-operating: -1,000 to 40,000 ft
|
Relative humidity range
|
-
Operational environment: 8% to 80%
noncondensing
-
Storage and transit environment: 5% to 95%
noncondensing
-
Non-operating: -20°C to 75°C noncondensing
|
Airflow requirement
|
More than 400 LFM (linear feet/minute) at 55°C, with airflow
towards IO bracket
|
|
Note -
For specific site planning guidelines and best practices, refer to the server documentation
and product notes for your server. Refer to the system site planning guide, if available.