4 Default IP Addresses and Ports Used in Exalogic Machine

This chapter lists the default ILOM, NET0, InfiniBand Bonded IP addresses, and ports assigned to Exalogic machine components during manufacturing.

This chapter contains the following sections:

Tip:

For more information about how these interfaces are used, see Figure 6-1, "Network Diagram for Exalogic Machine".

4.1 Exalogic Machine Full Rack

Table 4-1 lists the default ILOM, NET0, and Infiniband Bonded IP addresses assigned during manufacturing to Exalogic compute nodes and other hardware components in an Exalogic machine Full Rack.

Table 4-1 Default ILOM, NET0, and IB Bonded IP for Exalogic Full Rack

Unit Component (Front View) ILOM IP Address NET0 IP Address IB Bonded IP Address

42

Compute Node

192.168.1.132

192.168.1.32

192.168.10.32

41

Compute Node

192.168.1.131

192.168.1.31

192.168.10.31

40

Compute Node

192.168.1.130

192.168.1.30

192.168.10.30

39

Compute Node

192.168.1.129

192.168.1.29

192.168.10.29

38

Compute Node

192.168.1.128

192.168.1.28

192.168.10.28

37

Compute Node

192.168.1.127

192.168.1.27

192.168.10.27

36

Compute Node

192.168.1.126

192.168.1.26

192.168.10.26

35

Compute Node

192.168.1.125

192.168.1.25

192.168.10.25

34

Compute Node

192.168.1.124

192.168.1.24

192.168.10.24

33

Compute Node

192.168.1.123

192.168.1.23

192.168.10.23

32

Compute Node

192.168.1.122

192.168.1.22

192.168.10.22

31

Compute Node

192.168.1.121

192.168.1.21

192.168.10.21

30

Compute Node

192.168.1.120

192.168.1.20

192.168.10.20

29

Compute Node

192.168.1.119

192.168.1.19

192.168.10.19

28

Compute Node

192.168.1.118

192.168.1.18

192.168.10.18

27

Compute Node

192.168.1.117

192.168.1.17

192.168.10.17

26

Sun Network QDR InfiniBand Gateway Switch

192.168.1.204

Not applicable

Not applicable

25

Cisco Management Switch

192.168.1.200

Not applicable

Not applicable

24

Sun Network QDR InfiniBand Gateway Switch

192.168.1.203

Not applicable

Not applicable

23

Sun Network QDR InfiniBand Gateway Switch

192.168.1.202

Not applicable

Not applicable

22

X4170 M2 Server Head for the Sun ZFS Storage 7320 appliance

192.168.1.116

192.168.1.16

192.168.10.16

21

X4170 M2 Server Head for the Sun ZFS Storage 7320 appliance

192.168.1.115

192.168.1.15

192.168.10.15

20

Disk Storage Tray for the Sun ZFS Storage 7320 appliance

Not applicable

Not applicable

Not applicable

19

18

17

16

Sun Network QDR InfiniBand Gateway Switch

192.168.1.201

Not applicable

Not applicable

15

Compute Node

192.168.1.114

192.168.1.14

192.168.10.14

14

Compute Node

192.168.1.113

192.168.1.13

192.168.10.13

13

Compute Node

192.168.1.112

192.168.1.12

192.168.10.12

12

Compute Node

192.168.1.111

192.168.1.11

192.168.10.11

11

Compute Node

192.168.1.110

192.168.1.10

192.168.10.10

10

Compute Node

192.168.1.109

192.168.1.9

192.168.10.9

9

Compute Node

192.168.1.108

192.168.1.8

192.168.10.8

8

Compute Node

192.168.1.107

192.168.1.7

192.168.10.7

7

Compute Node

192.168.1.106

192.168.1.6

192.168.10.6

6

Compute Node

192.168.1.105

192.168.1.5

192.168.10.5

5

Compute Node

192.168.1.104

192.168.1.4

192.168.10.4

4

Compute Node

192.168.1.103

192.168.1.3

192.168.10.3

3

Compute Node

192.168.1.102

192.168.1.2

192.168.10.2

2

Compute Node

192.168.1.101

192.168.1.1

192.168.10.1

1

Sun Datacenter InfiniBand Switch 36

192.168.1.205

Not applicable

Not applicable

-

-

PDU-A (left from rear view)

192.168.1.210

Not applicable

Not applicable

PDU-B (right from rear view)

192.168.1.211

Not applicable

Not applicable


Note:

For X2-2: Compute Node refers to Sun Fire X4170 M2 and Cisco Management Switch refers to Cisco 4948 Management Switch.

For X3-2: Compute Node refers to Sun Server X3-2 and Cisco Management Switch refers to Cisco 4948E-F-S Management Switch.

4.2 Exalogic Machine Half Rack

Table 4-2 lists the default ILOM, NET0, and Infiniband Bonded IP addresses assigned during manufacturing to Exalogic compute nodes and other hardware components in an Exalogic machine half rack.

Table 4-2 Default ILOM, NET0, and IB Bonded IP for Exalogic Half Rack

Unit Rack Component (Front View) ILOM IP Address NET0 IP Address IB Bonded IP Address

42

4U Solid Filler

Not applicable

Not applicable

Not applicable

41

Not applicable

Not applicable

Not applicable

40

Not applicable

Not applicable

Not applicable

39

Not applicable

Not applicable

Not applicable

38

4U Solid Filler

Not applicable

Not applicable

Not applicable

37

Not applicable

Not applicable

Not applicable

36

Not applicable

Not applicable

Not applicable

35

Not applicable

Not applicable

Not applicable

34

4U Solid Filler

Not applicable

Not applicable

Not applicable

33

Not applicable

Not applicable

Not applicable

32

Not applicable

Not applicable

Not applicable

31

Not applicable

Not applicable

Not applicable

30

2U Solid Filler

Not applicable

Not applicable

Not applicable

29

Not applicable

Not applicable

Not applicable

28

Compute Node

192.168.1.118

192.168.1.18

192.168.10.18

27

Compute Node

192.168.1.117

192.168.1.17

192.168.10.17

26

1U Solid Filler

Not applicable

Not applicable

Not applicable

25

Cisco Management Switch

192.168.1.200

Not applicable

Not applicable

24

1U Solid Filler

Not applicable

Not applicable

Not applicable

23

Sun Network QDR InfiniBand Gateway Switch

192.168.1.202

Not applicable

Not applicable

22

X4170 M2 Server Head for the Sun ZFS Storage 7320 appliance

192.168.1.116

192.168.1.16

192.168.10.16

21

X4170 M2 Server Head for the Sun ZFS Storage 7320 appliance

192.168.1.115

192.168.1.15

192.168.10.15

20

Disk Storage Tray for the Sun ZFS Storage 7320 appliance

Not applicable

Not applicable

Not applicable

19

18

17

16

Sun Network QDR InfiniBand Gateway Switch

192.168.1.201

Not applicable

Not applicable

15

Compute Node

192.168.1.114

192.168.1.14

192.168.10.14

14

Compute Node

192.168.1.113

192.168.1.13

192.168.10.13

13

Compute Node

192.168.1.112

192.168.1.12

192.168.10.12

12

Compute Node

192.168.1.111

192.168.1.11

192.168.10.11

11

Compute Node

192.168.1.110

192.168.1.10

192.168.10.10

10

Compute Node

192.168.1.109

192.168.1.9

192.168.10.9

9

Compute Node

192.168.1.108

192.168.1.8

192.168.10.8

8

Compute Node

192.168.1.107

192.168.1.7

192.168.10.7

7

Compute Node

192.168.1.106

192.168.1.6

192.168.10.6

6

Compute Node

192.168.1.105

192.168.1.5

192.168.10.5

5

Compute Node

192.168.1.104

192.168.1.4

192.168.10.4

4

Compute Node

192.168.1.103

192.168.1.3

192.168.10.3

3

Compute Node

192.168.1.102

192.168.1.2

192.168.10.2

2

Compute Node

192.168.1.101

192.168.1.1

192.168.10.1

1

Sun Datacenter InfiniBand Switch 36

192.168.1.205

Not applicable

Not applicable

-

-

PDU-A (left from rear view)

192.168.1.210

Not applicable

Not applicable

PDU-B (right from rear view)

192.168.1.211

Not applicable

Not applicable


Note:

For X2-2: Compute Node refers to Sun Fire X4170 M2 and Cisco Management Switch refers to Cisco 4948 Management Switch.

For X3-2: Compute Node refers to Sun Server X3-2 and Cisco Management Switch refers to Cisco 4948E-F-S Management Switch.

4.3 Exalogic Machine Quarter Rack

Table 4-3 lists the default ILOM, NET0, and Infiniband Bonded IP addresses assigned during manufacturing to Exalogic compute nodes and other hardware components in an Exalogic machine quarter rack.

Table 4-3 Default ILOM, NET0, and IB Bonded IP for Exalogic Quarter Rack

Unit Rack Component (Front View) ILOM IP Address NET0 IP Address InfiniBand Bonded IP Address

42

4U Solid Filler

Not applicable

Not applicable

Not applicable

41

Not applicable

Not applicable

Not applicable

40

Not applicable

Not applicable

Not applicable

39

Not applicable

Not applicable

Not applicable

38

4U Solid Filler

Not applicable

Not applicable

Not applicable

37

Not applicable

Not applicable

Not applicable

36

Not applicable

Not applicable

Not applicable

35

Not applicable

Not applicable

Not applicable

34

4U Solid Filler

Not applicable

Not applicable

Not applicable

33

Not applicable

Not applicable

Not applicable

32

Not applicable

Not applicable

Not applicable

31

Not applicable

Not applicable

Not applicable

30

2U Solid Filler

Not applicable

Not applicable

Not applicable

29

Not applicable

Not applicable

Not applicable

28

2U Solid Filler

Not applicable

Not applicable

Not applicable

27

Not applicable

Not applicable

Not applicable

26

1U Solid Filler

Not applicable

Not applicable

Not applicable

25

Cisco Management Switch

192.168.1.200

Not applicable

Not applicable

24

1U Solid Filler

Not applicable

Not applicable

Not applicable

23

Sun Network QDR InfiniBand Gateway Switch

192.168.1.202

Not applicable

Not applicable

22

X4170 M2 Server Head for the Sun ZFS Storage 7320 appliance

192.168.1.116

192.168.1.16

192.168.10.16

21

X4170 M2 Server Head for the Sun ZFS Storage 7320 appliance

192.168.1.115

192.168.1.15

192.168.10.15

20

Disk Storage Tray for the Sun ZFS Storage 7320 appliance

Not applicable

Not applicable

Not applicable

19

18

17

16

Sun Network QDR InfiniBand Gateway Switch

192.168.1.201

Not applicable

Not applicable

15

2U Solid Filler

Not applicable

Not applicable

Not applicable

14

Not applicable

Not applicable

Not applicable

13

4U Solid Filler

Not applicable

Not applicable

Not applicable

12

Not applicable

Not applicable

Not applicable

11

Not applicable

Not applicable

Not applicable

10

Not applicable

Not applicable

Not applicable

9

Compute Node

192.168.1.108

192.168.1.8

192.168.10.8

8

Compute Node

192.168.1.107

192.168.1.7

192.168.10.7

7

Compute Node

192.168.1.106

192.168.1.6

192.168.10.6

6

Compute Node

192.168.1.105

192.168.1.5

192.168.10.5

5

Compute Node

192.168.1.104

192.168.1.4

192.168.10.4

4

Compute Node

192.168.1.103

192.168.1.3

192.168.10.3

3

Compute Node

192.168.1.102

192.168.1.2

192.168.10.2

2

Compute Node

192.168.1.101

192.168.1.1

192.168.10.1

1

1U Solid Filler

Not applicable

Not applicable

Not applicable

-

-

PDU-A (left from rear view)

192.168.1.210

Not applicable

Not applicable

PDU-B (right from rear view)

192.168.1.211

Not applicable

Not applicable


Note:

For X2-2: Compute Node refers to Sun Fire X4170 M2 and Cisco Management Switch refers to Cisco 4948 Management Switch.

For X3-2: Compute Node refers to Sun Server X3-2 and Cisco Management Switch refers to Cisco 4948E-F-S Management Switch.

4.4 Exalogic Machine Eighth Rack

Table 4-4 lists the default ILOM, NET0, and Infiniband Bonded IP addresses assigned during manufacturing to Exalogic compute nodes and other hardware components in an Exalogic machine eighth rack.

Table 4-4 Default ILOM, NET0, and IB Bonded IP for Exalogic Eighth Rack

Unit Rack Component (Front View) ILOM IP Address NET0 IP Address InfiniBand Bonded IP Address

42

4U Solid Filler

Not applicable

Not applicable

Not applicable

41

Not applicable

Not applicable

Not applicable

40

Not applicable

Not applicable

Not applicable

39

Not applicable

Not applicable

Not applicable

38

4U Solid Filler

Not applicable

Not applicable

Not applicable

37

Not applicable

Not applicable

Not applicable

36

Not applicable

Not applicable

Not applicable

35

Not applicable

Not applicable

Not applicable

34

4U Solid Filler

Not applicable

Not applicable

Not applicable

33

Not applicable

Not applicable

Not applicable

32

Not applicable

Not applicable

Not applicable

31

Not applicable

Not applicable

Not applicable

30

2U Solid Filler

Not applicable

Not applicable

Not applicable

29

Not applicable

Not applicable

Not applicable

28

2U Solid Filler

Not applicable

Not applicable

Not applicable

27

Not applicable

Not applicable

Not applicable

26

1U Solid Filler

Not applicable

Not applicable

Not applicable

25

Cisco Management Switch

192.168.1.200

Not applicable

Not applicable

24

1U Solid Filler

Not applicable

Not applicable

Not applicable

23

Sun Network QDR InfiniBand Gateway Switch

192.168.1.202

Not applicable

Not applicable

22

X4170 M2 Server Head for the Sun ZFS Storage 7320 appliance

192.168.1.116

192.168.1.16

192.168.10.16

21

X4170 M2 Server Head for the Sun ZFS Storage 7320 appliance

192.168.1.115

192.168.1.15

192.168.10.15

20

Disk Storage Tray for the Sun ZFS Storage 7320 appliance

Not applicable

Not applicable

Not applicable

19

18

17

16

Sun Network QDR InfiniBand Gateway Switch

192.168.1.201

Not applicable

Not applicable

15

2U Solid Filler

Not applicable

Not applicable

Not applicable

14

Not applicable

Not applicable

Not applicable

13

4U Solid Filler

Not applicable

Not applicable

Not applicable

12

Not applicable

Not applicable

Not applicable

11

Not applicable

Not applicable

Not applicable

10

Not applicable

Not applicable

Not applicable

9

4U Solid Filler

Not applicable

Not applicable

Not applicable

8

Not applicable

Not applicable

Not applicable

7

Not applicable

Not applicable

Not applicable

6

Not applicable

Not applicable

Not applicable

5

Compute Node

192.168.1.104

192.168.1.4

192.168.10.4

4

Compute Node

192.168.1.103

192.168.1.3

192.168.10.3

3

Compute Node

192.168.1.102

192.168.1.2

192.168.10.2

2

Compute Node

192.168.1.101

192.168.1.1

192.168.10.1

1

1U Solid Filler

Not applicable

Not applicable

Not applicable

-

-

PDU-A (left from rear view)

192.168.1.210

Not applicable

Not applicable

PDU-B (right from rear view)

192.168.1.211

Not applicable

Not applicable


Note:

For X2-2: Compute Node refers to Sun Fire X4170 M2 and Cisco Management Switch refers to Cisco 4948 Management Switch.

For X3-2: Compute Node refers to Sun Server X3-2 and Cisco Management Switch refers to Cisco 4948E-F-S Management Switch.