4 Default IP Addresses and Ports Used in Exalogic Machine

This chapter lists the default ILOM, NET0, InfiniBand Bonded IP addresses, and ports assigned to Exalogic machine components during manufacturing.

This chapter contains the following sections:

Tip:

For more information about how these interfaces are used, see Figure 6-1, "Network Diagram for Exalogic Machine".

4.1 Exalogic Machine Full Rack

Table 4-1 lists the default ILOM, NET0, and InfiniBand Bonded IP addresses assigned during manufacturing to Exalogic compute nodes and other hardware components in an Exalogic machine Full Rack.

Table 4-1 Default ILOM, NET0, and IB Bonded IP for Exalogic Full Rack

Unit Component (Front View) ILOM IP Address NET0 IP Address IB Bonded IP Address

42

Compute Node

192.168.1.132

192.168.1.32

192.168.10.32

41

Compute Node

192.168.1.131

192.168.1.31

192.168.10.31

40

Compute Node

192.168.1.130

192.168.1.30

192.168.10.30

39

Compute Node

192.168.1.129

192.168.1.29

192.168.10.29

38

Compute Node

192.168.1.128

192.168.1.28

192.168.10.28

37

Compute Node

192.168.1.127

192.168.1.27

192.168.10.27

36

Compute Node

192.168.1.126

192.168.1.26

192.168.10.26

35

Compute Node

192.168.1.125

192.168.1.25

192.168.10.25

34

Compute Node

192.168.1.124

192.168.1.24

192.168.10.24

33

Compute Node

192.168.1.123

192.168.1.23

192.168.10.23

32

Compute Node

192.168.1.122

192.168.1.22

192.168.10.22

31

Compute Node

192.168.1.121

192.168.1.21

192.168.10.21

30

Compute Node

192.168.1.120

192.168.1.20

192.168.10.20

29

Compute Node

192.168.1.119

192.168.1.19

192.168.10.19

28

Compute Node

192.168.1.118

192.168.1.18

192.168.10.18

27

Compute Node

192.168.1.117

192.168.1.17

192.168.10.17

26

Sun Network QDR InfiniBand Gateway Switch

192.168.1.204

Not applicable

Not applicable

25

Cisco Management Switch

Not applicable

192.168.1.200

Not applicable

24

Sun Network QDR InfiniBand Gateway Switch

192.168.1.203

Not applicable

Not applicable

23

Sun Network QDR InfiniBand Gateway Switch

192.168.1.202

Not applicable

Not applicable

22

Server head for the storage appliance

192.168.1.116

192.168.1.16

192.168.10.16

21

Server head for the storage appliance

192.168.1.115

192.168.1.15

192.168.10.15

20

Disk storage tray for the storage appliance

Not applicable

Not applicable

Not applicable

19

18

17

16

Sun Network QDR InfiniBand Gateway Switch

192.168.1.201

Not applicable

Not applicable

15

Compute Node

192.168.1.114

192.168.1.14

192.168.10.14

14

Compute Node

192.168.1.113

192.168.1.13

192.168.10.13

13

Compute Node

192.168.1.112

192.168.1.12

192.168.10.12

12

Compute Node

192.168.1.111

192.168.1.11

192.168.10.11

11

Compute Node

192.168.1.110

192.168.1.10

192.168.10.10

10

Compute Node

192.168.1.109

192.168.1.9

192.168.10.9

9

Compute Node

192.168.1.108

192.168.1.8

192.168.10.8

8

Compute Node

192.168.1.107

192.168.1.7

192.168.10.7

7

Compute Node

192.168.1.106

192.168.1.6

192.168.10.6

6

Compute Node

192.168.1.105

192.168.1.5

192.168.10.5

5

Compute Node

192.168.1.104

192.168.1.4

192.168.10.4

4

Compute Node

192.168.1.103

192.168.1.3

192.168.10.3

3

Compute Node

192.168.1.102

192.168.1.2

192.168.10.2

2

Compute Node

192.168.1.101

192.168.1.1

192.168.10.1

1

Sun Datacenter InfiniBand Switch 36

192.168.1.205

Not applicable

Not applicable

-

-

PDU-A (left from rear view)

192.168.1.210

Not applicable

Not applicable

PDU-B (right from rear view)

192.168.1.211

Not applicable

Not applicable


Note:

For X2-2: Compute Node refers to Sun Fire X4170 M2, Cisco Management Switch refers to Cisco 4948 Management Switch, and storage appliance refers to Sun ZFS 7320 storage appliance.

For X3-2: Compute Node refers to Sun Server X3-2, Cisco Management Switch refers to Cisco 4948E-F-S Management Switch, and storage appliance refers to Sun ZFS 7320 storage appliance.

For X4-2: Compute Node refers to Sun Server X4-2, Cisco Management Switch refers to Cisco 4948E-F-S Management Switch, and storage appliance refers to Oracle ZS3-ES storage appliance.

4.2 Exalogic Machine Half Rack

Table 4-2 lists the default ILOM, NET0, and InfiniBand Bonded IP addresses assigned during manufacturing to Exalogic compute nodes and other hardware components in an Exalogic machine half rack.

Table 4-2 Default ILOM, NET0, and IB Bonded IP for Exalogic Half Rack

Unit Rack Component (Front View) ILOM IP Address NET0 IP Address IB Bonded IP Address

42

4U Solid Filler

Not applicable

Not applicable

Not applicable

41

Not applicable

Not applicable

Not applicable

40

Not applicable

Not applicable

Not applicable

39

Not applicable

Not applicable

Not applicable

38

4U Solid Filler

Not applicable

Not applicable

Not applicable

37

Not applicable

Not applicable

Not applicable

36

Not applicable

Not applicable

Not applicable

35

Not applicable

Not applicable

Not applicable

34

4U Solid Filler

Not applicable

Not applicable

Not applicable

33

Not applicable

Not applicable

Not applicable

32

Not applicable

Not applicable

Not applicable

31

Not applicable

Not applicable

Not applicable

30

2U Solid Filler

Not applicable

Not applicable

Not applicable

29

Not applicable

Not applicable

Not applicable

28

Compute Node

192.168.1.118

192.168.1.18

192.168.10.18

27

Compute Node

192.168.1.117

192.168.1.17

192.168.10.17

26

1U Solid Filler

Not applicable

Not applicable

Not applicable

25

Cisco Management Switch

Not applicable

192.168.1.200

Not applicable

24

1U Solid Filler

Not applicable

Not applicable

Not applicable

23

Sun Network QDR InfiniBand Gateway Switch

192.168.1.202

Not applicable

Not applicable

22

Server head for the storage appliance

192.168.1.116

192.168.1.16

192.168.10.16

21

Server head for the storage appliance

192.168.1.115

192.168.1.15

192.168.10.15

20

Disk storage tray for the storage appliance

Not applicable

Not applicable

Not applicable

19

18

17

16

Sun Network QDR InfiniBand Gateway Switch

192.168.1.201

Not applicable

Not applicable

15

Compute Node

192.168.1.114

192.168.1.14

192.168.10.14

14

Compute Node

192.168.1.113

192.168.1.13

192.168.10.13

13

Compute Node

192.168.1.112

192.168.1.12

192.168.10.12

12

Compute Node

192.168.1.111

192.168.1.11

192.168.10.11

11

Compute Node

192.168.1.110

192.168.1.10

192.168.10.10

10

Compute Node

192.168.1.109

192.168.1.9

192.168.10.9

9

Compute Node

192.168.1.108

192.168.1.8

192.168.10.8

8

Compute Node

192.168.1.107

192.168.1.7

192.168.10.7

7

Compute Node

192.168.1.106

192.168.1.6

192.168.10.6

6

Compute Node

192.168.1.105

192.168.1.5

192.168.10.5

5

Compute Node

192.168.1.104

192.168.1.4

192.168.10.4

4

Compute Node

192.168.1.103

192.168.1.3

192.168.10.3

3

Compute Node

192.168.1.102

192.168.1.2

192.168.10.2

2

Compute Node

192.168.1.101

192.168.1.1

192.168.10.1

1

Sun Datacenter InfiniBand Switch 36

192.168.1.205

Not applicable

Not applicable

-

-

PDU-A (left from rear view)

192.168.1.210

Not applicable

Not applicable

PDU-B (right from rear view)

192.168.1.211

Not applicable

Not applicable


Note:

For X2-2: Compute Node refers to Sun Fire X4170 M2, Cisco Management Switch refers to Cisco 4948 Management Switch, and storage appliance refers to Sun ZFS 7320 storage appliance.

For X3-2: Compute Node refers to Sun Server X3-2, Cisco Management Switch refers to Cisco 4948E-F-S Management Switch, and storage appliance refers to Sun ZFS 7320 storage appliance.

For X4-2: Compute Node refers to Sun Server X4-2, Cisco Management Switch refers to Cisco 4948E-F-S Management Switch, and storage appliance refers to Oracle ZS3-ES storage appliance.

4.3 Exalogic Machine Quarter Rack

Table 4-3 lists the default ILOM, NET0, and InfiniBand Bonded IP addresses assigned during manufacturing to Exalogic compute nodes and other hardware components in an Exalogic machine quarter rack.

Table 4-3 Default ILOM, NET0, and IB Bonded IP for Exalogic Quarter Rack

Unit Rack Component (Front View) ILOM IP Address NET0 IP Address InfiniBand Bonded IP Address

42

4U Solid Filler

Not applicable

Not applicable

Not applicable

41

Not applicable

Not applicable

Not applicable

40

Not applicable

Not applicable

Not applicable

39

Not applicable

Not applicable

Not applicable

38

4U Solid Filler

Not applicable

Not applicable

Not applicable

37

Not applicable

Not applicable

Not applicable

36

Not applicable

Not applicable

Not applicable

35

Not applicable

Not applicable

Not applicable

34

4U Solid Filler

Not applicable

Not applicable

Not applicable

33

Not applicable

Not applicable

Not applicable

32

Not applicable

Not applicable

Not applicable

31

Not applicable

Not applicable

Not applicable

30

2U Solid Filler

Not applicable

Not applicable

Not applicable

29

Not applicable

Not applicable

Not applicable

28

2U Solid Filler

Not applicable

Not applicable

Not applicable

27

Not applicable

Not applicable

Not applicable

26

1U Solid Filler

Not applicable

Not applicable

Not applicable

25

Cisco Management Switch

Not applicable

192.168.1.200

Not applicable

24

1U Solid Filler

Not applicable

Not applicable

Not applicable

23

Sun Network QDR InfiniBand Gateway Switch

192.168.1.202

Not applicable

Not applicable

22

Server head for the storage appliance

192.168.1.116

192.168.1.16

192.168.10.16

21

Server head for the storage appliance

192.168.1.115

192.168.1.15

192.168.10.15

20

Disk storage tray for the storage appliance

Not applicable

Not applicable

Not applicable

19

18

17

16

Sun Network QDR InfiniBand Gateway Switch

192.168.1.201

Not applicable

Not applicable

15

2U Solid Filler

Not applicable

Not applicable

Not applicable

14

Not applicable

Not applicable

Not applicable

13

4U Solid Filler

Not applicable

Not applicable

Not applicable

12

Not applicable

Not applicable

Not applicable

11

Not applicable

Not applicable

Not applicable

10

Not applicable

Not applicable

Not applicable

9

Compute Node

192.168.1.108

192.168.1.8

192.168.10.8

8

Compute Node

192.168.1.107

192.168.1.7

192.168.10.7

7

Compute Node

192.168.1.106

192.168.1.6

192.168.10.6

6

Compute Node

192.168.1.105

192.168.1.5

192.168.10.5

5

Compute Node

192.168.1.104

192.168.1.4

192.168.10.4

4

Compute Node

192.168.1.103

192.168.1.3

192.168.10.3

3

Compute Node

192.168.1.102

192.168.1.2

192.168.10.2

2

Compute Node

192.168.1.101

192.168.1.1

192.168.10.1

1

1U Solid Filler

Not applicable

Not applicable

Not applicable

-

-

PDU-A (left from rear view)

192.168.1.210

Not applicable

Not applicable

PDU-B (right from rear view)

192.168.1.211

Not applicable

Not applicable


Note:

For X2-2: Compute Node refers to Sun Fire X4170 M2, Cisco Management Switch refers to Cisco 4948 Management Switch, and storage appliance refers to Sun ZFS 7320 storage appliance.

For X3-2: Compute Node refers to Sun Server X3-2, Cisco Management Switch refers to Cisco 4948E-F-S Management Switch, and storage appliance refers to Sun ZFS 7320 storage appliance.

For X4-2: Compute Node refers to Sun Server X4-2, Cisco Management Switch refers to Cisco 4948E-F-S Management Switch, and storage appliance refers to Oracle ZS3-ES storage appliance.

4.4 Exalogic Machine Eighth Rack

Table 4-4 lists the default ILOM, NET0, and InfiniBand Bonded IP addresses assigned during manufacturing to Exalogic compute nodes and other hardware components in an Exalogic machine eighth rack.

Table 4-4 Default ILOM, NET0, and IB Bonded IP for Exalogic Eighth Rack

Unit Rack Component (Front View) ILOM IP Address NET0 IP Address InfiniBand Bonded IP Address

42

4U Solid Filler

Not applicable

Not applicable

Not applicable

41

Not applicable

Not applicable

Not applicable

40

Not applicable

Not applicable

Not applicable

39

Not applicable

Not applicable

Not applicable

38

4U Solid Filler

Not applicable

Not applicable

Not applicable

37

Not applicable

Not applicable

Not applicable

36

Not applicable

Not applicable

Not applicable

35

Not applicable

Not applicable

Not applicable

34

4U Solid Filler

Not applicable

Not applicable

Not applicable

33

Not applicable

Not applicable

Not applicable

32

Not applicable

Not applicable

Not applicable

31

Not applicable

Not applicable

Not applicable

30

2U Solid Filler

Not applicable

Not applicable

Not applicable

29

Not applicable

Not applicable

Not applicable

28

2U Solid Filler

Not applicable

Not applicable

Not applicable

27

Not applicable

Not applicable

Not applicable

26

1U Solid Filler

Not applicable

Not applicable

Not applicable

25

Cisco Management Switch

Not applicable

192.168.1.200

Not applicable

24

1U Solid Filler

Not applicable

Not applicable

Not applicable

23

Sun Network QDR InfiniBand Gateway Switch

192.168.1.202

Not applicable

Not applicable

22

Server head for the storage appliance

192.168.1.116

192.168.1.16

192.168.10.16

21

Server head for the storage appliance

192.168.1.115

192.168.1.15

192.168.10.15

20

Disk storage tray for storage appliance

Not applicable

Not applicable

Not applicable

19

18

17

16

Sun Network QDR InfiniBand Gateway Switch

192.168.1.201

Not applicable

Not applicable

15

2U Solid Filler

Not applicable

Not applicable

Not applicable

14

Not applicable

Not applicable

Not applicable

13

4U Solid Filler

Not applicable

Not applicable

Not applicable

12

Not applicable

Not applicable

Not applicable

11

Not applicable

Not applicable

Not applicable

10

Not applicable

Not applicable

Not applicable

9

4U Solid Filler

Not applicable

Not applicable

Not applicable

8

Not applicable

Not applicable

Not applicable

7

Not applicable

Not applicable

Not applicable

6

Not applicable

Not applicable

Not applicable

5

Compute Node

192.168.1.104

192.168.1.4

192.168.10.4

4

Compute Node

192.168.1.103

192.168.1.3

192.168.10.3

3

Compute Node

192.168.1.102

192.168.1.2

192.168.10.2

2

Compute Node

192.168.1.101

192.168.1.1

192.168.10.1

1

1U Solid Filler

Not applicable

Not applicable

Not applicable

-

-

PDU-A (left from rear view)

192.168.1.210

Not applicable

Not applicable

PDU-B (right from rear view)

192.168.1.211

Not applicable

Not applicable


Note:

For X2-2: Compute Node refers to Sun Fire X4170 M2, Cisco Management Switch refers to Cisco 4948 Management Switch, and storage appliance refers to Sun ZFS 7320 storage appliance.

For X3-2: Compute Node refers to Sun Server X3-2, Cisco Management Switch refers to Cisco 4948E-F-S Management Switch, and storage appliance refers to Sun ZFS 7320 storage appliance.

For X4-2: Compute Node refers to Sun Server X4-2, Cisco Management Switch refers to Cisco 4948E-F-S Management Switch, and storage appliance refers to Oracle ZS3-ES storage appliance.

4.5 Default Port Assignments

Table 4-5 lists the default ports assigned to Exalogic compute nodes and other hardware components in an Exalogic machine.

Table 4-5 Default Ports

Source Target Protocol Port Application

Any

Compute nodes, storage appliance heads, and InfiniBand ILOMs

SSH over TCP

22

SSH

Any

Compute nodes, storage appliance heads, and InfiniBand ILOMs

HTTP over TCP

80

Web (user configurable)

Any

Compute nodes, storage appliance heads, and InfiniBand ILOMs

SNMP over UDP

161

SNMP (Simple Network Management Protocol) (user configurable)

Any

Compute nodes, storage appliance heads, and InfiniBand ILOMs

LDAP over UDP/TCP

389

Outgoing LDAP (Lightweight Directory Access Protocol) (user configurable)

Any

Compute nodes, storage appliance heads, and InfiniBand ILOMs

HTTPS over TCP

443

Web (user configurable)

Any

Compute nodes, storage appliance heads, and InfiniBand ILOMs

IPMI over UDP

623

IPMI (Intelligent Platform Management Interface)

Any

Compute nodes, and storage appliance heads ILOMs

TCP

5120

ILOM remote console: CD

Any

Compute nodes, and storage appliance heads ILOMs

TCP

5121

ILOM remote console: keyboard and mouse

Any

Compute nodes, and storage appliance heads ILOMs

TCP

5123

ILOM remote console: diskette

Any

Compute nodes, and storage appliance heads ILOMs

TCP

5555

ILOM remote console: encryption

Any

Compute nodes, and storage appliance heads ILOMs

TCP

6481

ILOM remote console: Servicetag daemon

Any

Compute nodes, and storage appliance heads ILOMs

TCP

5556

ILOM remote console: authentication

Any

Compute nodes, and storage appliance heads ILOMs

TCP

7578

ILOM remote console: video

Any

Compute nodes, and storage appliance heads ILOMs

TCP

7579

ILOM remote console: serial

ASR Manager

Compute nodes, and storage appliance heads ILOMs

HTTP

6481

Service tags listener for asset activation

Compute nodes, storage appliance heads, and InfiniBand ILOMs

Any

TFTP over UDP

69

Outgoing TFTP (Trivial File Transfer Protocol)

Compute nodes, storage appliance heads, and InfiniBand ILOMs

Any

NTP over UDP

123

Outgoing NTP

Compute nodes, storage appliance heads, and InfiniBand ILOMs

Any

IPMI over UDP

162

Outgoing IPMI (Intelligent Platform Management Interface) Platform Event Trap (PET)

Compute nodes, storage appliance heads, and InfiniBand ILOMs

Any

Syslog over UDP

514

Outgoing Syslog

Compute nodes, storage appliance heads, and InfiniBand ILOMs

Any

DHCP over UDP

546

Client DHCP (Dynamic Host Configuration Protocol)

Compute nodes, storage appliance heads, and InfiniBand ILOMs

Any

RADIUS over UDP

1812

Outgoing RADIUS (Remote Authentication Dial In User Service) (user configurable)

Compute nodes, and storage appliance heads ILOMs

ASR Manager

SNMP

162

Telemetry messages sent to ASR Manager

Any

Storage appliance

HTTP over TCP

215

Browser interface

Storage management

Any

NTP over UDP

123

Outgoing NTP

Any

PDU

HTTP over TCP

80

Browser interface

Any

PDU

SNMP over UDP

161

SNMP (user configurable)

Any

PDU

HTTPS over TCP

443

Browser interface

PDU

Any

SNMP over UDP

162

Outgoing SNMPv2 traps

PDU

Any

Syslog over UDP

514

Outgoing Syslog

PDU

Any

DHCP over UDP

546

DHCP (Dynamic Host Configuration Protocol) client