Exit Print View

Sun Datacenter InfiniBand Switch 648 Topic Set

Get PDF Book Print View
 

Document Information

Using This Documentation

Related Documentation

Documentation, Support, and Training

Documentation Feedback

Installation

Preparing the Site

Installing the Switch

Administration

Administering the Switch

Diagnosing a Problem

Remote Management

Understanding ILOM on the Switch

Installing the ILOM Firmware

Administering ILOM (CLI)

Administering ILOM (Web Interface)

Administering ILOM (SNMP)

Administering Hardware (IPMI)

Understanding ILOM Commands

Service

Servicing the Switch

Reference

Command Reference

Understanding Switch-Specific Commands

activate Command (switch-specific)

checkfans Command

checklinks Command

checkpowers Command

checkpwrfault Command

checkswitches Command

checkvoltages Command

clearboardstat Command

deactivate Command (switch-specific)

disableboard Command

disablepsu Command

disablestby Command

disableswitchport Command

enableboard Command

enablehotinsert Command

enablepsu Command

enablestby Command

enableswitchport Command

env_test Command

findport Command

getbaseguid Command

getboardstat Command

getfwversion Command

getportcounters Command

getportstatus Command

getpsufwver Command

getserialnumbers Command

getsymerr Command

i2ctest Command

m9diag Command

mcmversion Command

psustatus Command

resetswitch Command

selectdebugport Command

setlinkspeed Command

showlogs Command

showpresent Command

showtemps Command

showvoltages Command

Understanding CLIA Commands

activate Command (CLIA)

deactivate Command (CLIA)

exit Command (CLIA)

fru Command

frucontrol Command

fruinfo Command

getfruledstate Command

getipmbstate Command

getlanconfig Command

LAN Configuration Parameters

help Command (CLIA)

ipmc Command

localaddress Command

poll Command

quit Command

sel Command

sensordata Command

session Command

setextracted Command

setfruledstate Command

setipmbstate Command

setlanconfig Command

setlocked Command

shelf Command

shelfaddress Command

shmstatus Command

showunhealthy Command

switchover Command

terminate Command

user [-v] Command

user add Command

user channel Command

user delete Command

user enable Command

user name Command

user passwd Command

version Command (CLIA)

Understanding InfiniBand Software Commands

ib_read_bw Command

ib_read_lat Command

ib_send_bw Command

ib_send_lat Command

ib_write_bw Command

ib_write_lat Command

ibaddr Command

ibcheckerrors Command

ibchecknet Command

ibchecknode Command

ibcheckport Command

ibcheckportstate Command

ibcheckportwidth Command

ibcheckstate Command

ibcheckwidth Command

ibclearcounters Command

ibclearerrors Command

ibdatacounters Command

ibdatacounts Command

ibdiagnet Command

ibdiagpath Command

ibhosts Command

ibnetdiscover Command

ibnodes Command

ibping Command

ibportstate Command

ibroute Command

ibrouters Command

ibstat Command

ibstatus Command

ibswitches Command

ibsysstat Command

ibtracert Command

ibv_devices Command

ibv_devinfo Command

ibv_rc_pingpong Command

ibv_srq_pingpong Command

ibv_uc_pingpong Command

ibv_ud_pingpong Command

ofed_info Command

opensm Command

opensmd Daemon

osmtest Command

perfquery Command

saquery Command

sminfo Command

smpdump Command

smpquery Command

vendstat Command

Index

shelf Command

Displays shelf FRU information. Issued on the CMC.

Syntax

shelf [-v] command_parameter

where command_parameter is:

Description

The shelf command shows key shelf FRU information, plus selected current operating data for the shelf.

The following table lists the parameters supported by the shelf command:

Command Parameter
Information Provided by the Command Parameter
cooling_state

(abbreviated as cs)

Shows the current cooling state of the shelf:
  • Normal – All temperature sensors show normal operating temperature.

  • Minor Alert – At least one temperature sensor is in minor alert state. None of the sensors is in major or critical alert state.

  • Major Alert – At least one temperature sensor is in major alert state. None of the sensors is in critical alert state.

  • Critical Alert – At least one temperature sensor is in critical alert state.

fans_state

(abbreviated as fs)

Shows the current state of the fan tachometers in the shelf:
  • Normal – All fan tachometer sensors show normal operating speed.

  • Minor Alert – At least one fan tachometer sensor is in minor alert state. None of the sensors is in major or critical alert state.

  • Major Alert – At least one fan tachometer sensor is in major alert state. None of the sensors is in critical alert state.

  • Critical Alert – At least one fan tachometer sensor is in critical alert state.

address_table

(abbreviated as at)

Shows the Address Table record in the Shelf FRU Info. The following information is provided:
  • Shelf Address (shown according to its type).

  • List of address table entries, showing Hardware Address, Site Number, and Site Type for each entry.

power_distribution

(abbreviated as pd)

The following information is provided for each of the power feeds (mostly from the Shelf Power Distribution record of the Shelf FRU Information):
  • Maximum External Available Current.

  • Maximum Internal Current.

  • Minimum Expected Operating Voltage.

  • Actual Power Available.

  • Currently Used Power.

  • List of FRUs connected to the feed, showing Hardware Address and FRU Device ID for each FRU.

power_management

(abbreviated as pm)

The Shelf Power Management record in the Shelf FRU Info. This record contains a list of FRU Power Descriptors. For each descriptor the following information is provided:
  • Hardware Address.

  • FRU Device ID.

  • Maximum FRU Power Capability.

  • Shelf Manager Controlled Activation.

  • Delay Before Next Power On.

pci_connectivity

(abbreviated as pcic)

The Shelf PCI Connectivity record in the Shelf FRU Info. The following information is provided:
  • PCI Slot Descriptor.

  • DSEL Connection.

  • Segment ID.

  • Extended PCI Slot Descriptor.

  • Geographic Address.

  • Interface Number.

  • System Slot Capable.

ha_connectivity

(abbreviated as ha)

The Shelf HA Connectivity record in the Shelf FRU Info. The following information is provided:

Radial Connectivity Support.

h110_connectivity

(abbreviated as h110c)

The Shelf H110 Connectivity record in the Shelf FRU Info. The following information is provided:
  • Geographic Address.

  • Segment ID.

point_to_point_connectivity

(abbreviated as ppc)

The Shelf Point-to-Point Connectivity record in the Shelf FRU Info. The following information is provided:
  • Channel Type.

  • Channel Count.

  • Slot/ HW Address.

  • Channel Descriptor.

Options

For the command parameters cooling_state and fans_state, the verbosity option -v is available. The option displays the list of sensors (temperature or fan tachometers) that contribute to the current state. Each sensor is shown as a tuple (IPMB_address, sensor_number).

Example

The following example shows how to display the IPMB addresses with the shelf command.

# clia shelf address_table 
Pigeon Point Shelf Manager Command Line Interpreter
 PICMG Address Table Record (ID=0x10)
 Version = 1
 Shelf Address            = 0x10
 Address Table Entries#   = 27
     Hw Addr: 08 (10), Site # 1, Type: "Dedicated ShMC" 03
     Hw Addr: 09 (12), Site # 2, Type: "Dedicated ShMC" 03
     Hw Addr: 10 (20), Site # 1, Type: "OEM" c0
     Hw Addr: 10 (20), Site # 1, Type: "Shelf FRU Information" 02
     Hw Addr: 10 (20), Site # 2, Type: "Shelf FRU Information" 02
     Hw Addr: 10 (20), Site # 1, Type: "Power Supply" c5
     Hw Addr: 10 (20), Site # 2, Type: "Power Supply" c5
     Hw Addr: 10 (20), Site # 3, Type: "Power Supply" c5
     Hw Addr: 10 (20), Site # 4, Type: "Power Supply" c5
     Hw Addr: 41 (82), Site # 1, Type: "AdvancedTCA Board" 00
     Hw Addr: 42 (84), Site # 2, Type: "AdvancedTCA Board" 00
     Hw Addr: 43 (86), Site # 3, Type: "AdvancedTCA Board" 00
     Hw Addr: 44 (88), Site # 4, Type: "AdvancedTCA Board" 00
     Hw Addr: 45 (8a), Site # 5, Type: "AdvancedTCA Board" 00
     Hw Addr: 46 (8c), Site # 6, Type: "AdvancedTCA Board" 00
     Hw Addr: 47 (8e), Site # 7, Type: "AdvancedTCA Board" 00
     Hw Addr: 48 (90), Site # 8, Type: "AdvancedTCA Board" 00
     Hw Addr: 49 (92), Site # 9, Type: "AdvancedTCA Board" 00
     Hw Addr: 4a (94), Site # 10, Type: "AdvancedTCA Board" 00
     Hw Addr: 4b (96), Site # 11, Type: "AdvancedTCA Board" 00
     Hw Addr: 4c (98), Site # 12, Type: "AdvancedTCA Board" 00
     Hw Addr: 4d (9a), Site # 13, Type: "AdvancedTCA Board" 00
     Hw Addr: 4e (9c), Site # 14, Type: "AdvancedTCA Board" 00
     Hw Addr: 4f (9e), Site # 15, Type: "AdvancedTCA Board" 00
     Hw Addr: 50 (a0), Site # 16, Type: "AdvancedTCA Board" 00
     Hw Addr: 51 (a2), Site # 17, Type: "AdvancedTCA Board" 00
     Hw Addr: 52 (a4), Site # 18, Type: "AdvancedTCA Board" 00
#