Documentation, Support, and Training
Understanding ILOM on the Switch
Administering ILOM (Web Interface)
Understanding Switch-Specific Commands
activate Command (switch-specific)
deactivate Command (switch-specific)
Displays components present. Issued on the CMC.
showpresent
This switch-specific command displays physically installed power supplies, line cards, and fabric cards. If a line card or fabric card is present, its activity is also displayed.
The following example shows how to display components sensed in the chassis with the showpresent command.
# showpresent PSU 00 present, state = ON PSU 01 present, state = ON PSU 02 present, state = ON PSU 03 present, state = ON FC 00 present and active (state = M4) FC 01 present but not active (state = M1) FC(F) 02 present but not active (state = unknown) FC 03 present and active (state = M4) FC 04 present and active (state = M4) . . . #
Note - The output in the examples are just a portion of the full output.
In this example, fabric card 1 has been deactivated. Because fabric card slot 2 has had standby voltage disabled, it is not possible for the CMC to determine if the component installed is a fabric card or a fabric card filler.
The string (state = M4) means the FRU is in an active state. Other states are identified by the following:
M0 – Not installed
M1 – Inactive
M2 – Activation request
M3 – Activation in progress
M4 – FRU active
M5 – Deactivation request
M6 – Deactivation in progress
M7 – Communication lost