Documentation, Support, and Training
Understanding ILOM on the Switch
Administering ILOM (Web Interface)
Understanding Switch-Specific Commands
activate Command (switch-specific)
deactivate Command (switch-specific)
Displays fan status. Issued on the CMC.
checkfans
This switch-specific command displays fan status for fabric cards 0 through 8. Each fabric card has four fans, 0 through 3. The output contains fan speeds or a warning message of fan failure.
The following example shows how to check fabric card fan status with the checkfans command.
# checkfans Checking M9 fans... FC 0 Fan 0 RPM = 21210.000000 FC 0 Fan 1 RPM = 21782.000000 Warning : FC 0 Fan 2 stopped FC 0 Fan 3 RPM = 21496.000000 FC 1 Fan 0 RPM = 22068.000000 FC 1 Fan 1 RPM = 21782.000000 FC 1 Fan 2 RPM = 21496.000000 FC 1 Fan 3 RPM = 21782.000000 . . . #
In the example, fan 2 of fabric card 0 has stopped.
Note - The output in the example is just a portion of the full output.