Skip Navigation Links | |
Exit Print View | |
![]() |
Sun Fire X4800 Server Diagnostics Guide Sun Fire X4800 Server Documentation |
About This Documentation (PDF and HTML)
Overview of the Diagnostics Guide
Introduction to System Diagnostics
How to Gather Service Visit Information
How to Troubleshoot Power Problems
How to Externally Inspect the Server
How to Internally Inspect the Server
Identifying DIMM Error Messages
Default BIOS Power-On Self-Test (POST) Events
Using the ILOM to Monitor the Host
Viewing the ILOM Sensor Readings
Viewing the ILOM System Event Log
Interpreting Event Log Time Stamps
Creating a Data Collector Snapshot
How to Create a Snapshot With the ILOM Web Interface
How to Create a Snapshot With the ILOM Command-Line Interface
Using SunVTS Diagnostics Software
Introduction to SunVTS Diagnostic Test Suite
How to Diagnose Server Problems With the Bootable Diagnostics CD
Performing Pc-Check Diagnostic Tests
This section contains information about how to troubleshoot DIMM problems.
In this section, the term “CPU module” or CMOD refers to a full CPU blade, including all CPUs and DIMMs on the blade. The term “CPU” refers to a single CPU.
Note - For information about Oracle’s DIMM replacement policy for x86 servers, contact your Oracle Service representative.
There are two ways to identify DIMM errors:
View the DIMM LEDs on the CPU modules (CMODs). See DIMM Fault LEDs.
View the ILOM System Event Log to view errors identified by the BIOS. See Identifying DIMM Error Messages .
See Correcting DIMM Errors for information on how to correct DIMM errors.