Chapter 2 Hardware Installation and Removal
Observing ESD and Handling Precautions
To Verify Proper Installation (Oracle SPARC)
To Verify Proper Installation (Oracle x86)
Replacing the SFP+ Unit on the HBA
In the example that follows, a storage JBOD has one target and two LUNs attached to one port of a dual port HBA.
{0} ok show-disks
a) /pci@0/pci@0/pci@8/pci@0/pci@2/SUNW,qlc@0,1/fp@0,0/disk
b) /pci@0/pci@0/pci@8/pci@0/pci@2/SUNW,qlc@0/fp@0,0/disk
c) /pci@0/pci@0/pci@2/scsi@0/disk
d) /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2/storage@2/disk
q) NO SELECTION
Enter Selection, q to quit: b
{0} ok select /pci@0/pci@0/pci@8/pci@0/pci@2/SUNW,qlc@0
QLogic QLE2562 Host Adapter FCode(SPARC): 2.03 06/30/08
Firmware version 4.03.02
{0} ok show-children
Adapter portID - 11000
************** Fabric Attached Devices **************
Dev# 0(0) PortID 100e8 Port WWN 21000011c68115b3
LUN 0(0) DISK SEAGATE ST336854FC 0005
Dev# 1(1) PortID 10100 Port WWN 201500a0b84718a4
LUN a(10) DISK STK FLEXLINE 380 0619
LUN b(11) DISK STK FLEXLINE 380 0619
{0} ok