Supported Versions of the OS, Firmware, and Software
Required OS Package and Patch Updates
Determining Oracle Solaris 11 OS Package Update Version
Identifying Drive Logical Device Names and Physical Locations
Correlate WWN Device Names With Physical Locations (diskinfo Command)
Correlate WWN Device Names With Physical Locations (probe-scsi-all Command)
Oracle Solaris Jumpstart WWN Syntax
Interactive Installation Example
High-Altitude Mode Oracle ILOM Feature
Sun Type 6 Keyboards Are Not Supported by SPARC and Netra SPARC T4 Series Servers
Chassis CMM Does Not Allocate Enough Power to the Netra T4-1B Server Module (CR 7141886)
PSH Might Not Clear a Retired Cache Line on a Replaced Motherboard (CR 7031216)
2-Meter USB Cable Length Limit (7048419)
During a Reboot After an Unrecoverable Hardware Error, CPUs Might Not Start (CR 7075336)
Blue LED on Drive Does Not Light When the Drive Is Ready to Remove (CR 7082700)
Firmware, OS, and Other Software Issues
fault.memory.memlink-uc Fault Did Not Cause Panic as Stated by System Message (CR 6940599)
Timestamp for an Oracle ILOM Fault/Critical Event Might Be off by One Hour (CR 6943957)
sas2ircu Message That RAID Volume Sizes Other Than MAX Are Not Supported (CR 6983210)
Fault Management Sometimes Sends Resolved Cases to the SP (CR 6983432)
Units Used to Define the MIB Power Management Time Limit Are Reported in Seconds (CR 6993008)
Spurious Interrupt Message in System Console When Using Oracle VTS (CR 7038266)
Intermittent Link Training Timeout Displayed During Power Cycles (CR 7043201)
The cfgadm Command Might Fail on SG-SAS6-REM-Z or SGX-SAS6-REM-Z HBAs (CR 7044759)
Message From cpustat Refers to Processor Documentation Incorrectly (CR 7046898)
The reboot disk Command Occasionally Fails When disk Argument Picks Up Extra Characters (CR 7050975)
Watchdog Timeouts Seen With Heavy Workloads and Maximum Memory Configurations (CR 7083001)
ereport.fm.fmd.module Generated During a Reboot of an SDIO Domain (CR 7085231)
Oracle VTS dtlbtest Hangs When CPU Threading Mode Is Set to max-ipc (CR 7094158)
In rare cases, PCIe Gen2 devices in the server module might report I/O errors that are identified and reported by predictive self-healing (PSH). For example:
--------------- ------------------------------------ -------------- ---------
TIME EVENT-ID MSG-ID SEVERITY
--------------- ------------------------------------ -------------- ---------
Aug 10 13:03:23 a7d43aeb-61ca-626a-f47b-c05635f2cf5a PCIEX-8000-KP Major
Host : dt214-154
Platform : ORCL,SPARC-T3-1B Chassis_id :
Product_sn :
Fault class : fault.io.pciex.device-interr-corr 67%
fault.io.pciex.bus-linkerr-corr 33%
Affects : dev:////pci@400/pci@1/pci@0/pci@c
dev:////pci@400/pci@1/pci@0/pci@c/pci@0
faulted but still in service
FRU : "/SYS/MB" (hc://:product-id=ORCL,SPARC-T3-1B:product-sn=1052NND107:server-id=dt214-154:chassis-id=0000000-0000000000:serial=1005LCB-1052D9008K:part=541-424304:revision=50/chassis=0/motherboard=0) 67%
"FEM0" (hc://:product-id=ORCL,SPARC-T3-1B:product-sn=1052NND107:server-id=dt214-154:chassis-id=0000000-0000000000/chassis=0/motherboard=0/hostbridge=0/pciexrc=0/pciexbus=1/pciexdev=0/pciexfn=0/pciexbus=2/pciexdev=12/pciexfn=0/pciexbus=62/pciexdev=0) 33%
faulty
Description : Too many recovered bus errors have been detected, which indicates
a problem with the specified bus or with the specified
transmitting device. This may degrade into an unrecoverable
fault.
Refer to http://sun.com/msg/PCIEX-8000-KP for more information.
Response : One or more device instances may be disabled
Impact : Loss of services provided by the device instances associated with
this fault
Action : If a plug-in card is involved check for badly-seated cards or
bent pins. Otherwise schedule a repair procedure to replace the
affected device. Use fmadm faulty to identify the device or
contact Sun for support.
These errors might be an indication of a faulty or incorrectly seated PCI EM. Or these errors might be erroneous.
Workaround: Ensure that the PCI EM is properly seated and functioning. If the errors continue, apply the Oracle Solaris 10 8/11 OS patch 147705-01 (or higher).