Supported Versions of the OS, Firmware, and Software
Required OS Package and Patch Updates
Determining Oracle Solaris 11 OS Package Update Version
Identifying Drive Logical Device Names and Physical Locations
Correlate WWN Device Names With Physical Locations (diskinfo Command)
Correlate WWN Device Names With Physical Locations (probe-scsi-all Command)
Oracle Solaris Jumpstart WWN Syntax
Interactive Installation Example
High-Altitude Mode Oracle ILOM Feature
Sun Type 6 Keyboards Are Not Supported by SPARC and Netra SPARC T4 Series Servers
Chassis CMM Does Not Allocate Enough Power to the Netra T4-1B Server Module (CR 7141886)
PSH Might Not Clear a Retired Cache Line on a Replaced Motherboard (CR 7031216)
2-Meter USB Cable Length Limit (7048419)
During a Reboot After an Unrecoverable Hardware Error, CPUs Might Not Start (CR 7075336)
Blue LED on Drive Does Not Light When the Drive Is Ready to Remove (CR 7082700)
Firmware, OS, and Other Software Issues
fault.memory.memlink-uc Fault Did Not Cause Panic as Stated by System Message (CR 6940599)
Timestamp for an Oracle ILOM Fault/Critical Event Might Be off by One Hour (CR 6943957)
sas2ircu Message That RAID Volume Sizes Other Than MAX Are Not Supported (CR 6983210)
Fault Management Sometimes Sends Resolved Cases to the SP (CR 6983432)
Units Used to Define the MIB Power Management Time Limit Are Reported in Seconds (CR 6993008)
Spurious Interrupt Message in System Console When Using Oracle VTS (CR 7038266)
Intermittent Link Training Timeout Displayed During Power Cycles (CR 7043201)
The cfgadm Command Might Fail on SG-SAS6-REM-Z or SGX-SAS6-REM-Z HBAs (CR 7044759)
Message From cpustat Refers to Processor Documentation Incorrectly (CR 7046898)
The reboot disk Command Occasionally Fails When disk Argument Picks Up Extra Characters (CR 7050975)
PCIe Correctable Errors Might Be Reported (CR 7051331)
Watchdog Timeouts Seen With Heavy Workloads and Maximum Memory Configurations (CR 7083001)
ereport.fm.fmd.module Generated During a Reboot of an SDIO Domain (CR 7085231)
Oracle VTS dtlbtest Hangs When CPU Threading Mode Is Set to max-ipc (CR 7094158)
When installing the Oracle Solaris OS on domains controlled through Sun PCIe Dual Gigabit Ethernet (UTP or MMF) adapters, the e1000g driver might generate false error reports on the static direct I/O (SDIO) and primary domains. For example:
date time ereport.io.pciex.tl.ca nvlist version: 0 ena = 0x298a9f62243802 ena = 0x298a9f62243802 detector = (embedded nvlist) nvlist version: 0 scheme = dev device-path = /pci@400/pci@1 (end detector) class = ereport.io.pciex.tl.ca dev-status = 0x2 ue-status = 0x8000 ue-severity = 0x62030 adv-ctl = 0xf source-id = 0x600 source-valid = 1 __ttl = 0x1 __tod = 0x4c058b2e 0x1e8813a0
Workaround: You can safely ignore these ereports.