Go to main content

SPARC T5-4 Server Installation Guide

Exit Print View

Updated: July 2015
 
 

Electrical Specifications

Use these specifications only as a general planning guide. To determine power values based on expected workloads, use theSPARC T5-4 power calculator located at this online site:

http://www.oracle.com/goto/powercalculators/

Description
Value
Operating input range
200 to 240 VAC,
50-60 Hz
Maximum operating input current at 200 VAC
(Actual amperage draw may exceed rating by no more than 10%)
15.3 A
Maximum operating input power at 200 VAC
(Actual power draw may exceed rating by no more than 10%)
3000W
Maximum heat dissipation
11,233 BTU/hr 11,851 KJ/hr
Maximum standby power
140W
Maximum server configuration specification under nominal temperature and voltage conditions:
(Four 3.6GHz T5 Processors, with sixty-four 32GB DDR3 DIMMS, 8 HDD and 16 I/O cards)
Idle input power
1495 W
Peak AC input power (running SpecJBB)
3292 W
Minimum server configuration specification under nominal temperature and voltage conditions
(Two 3.6GHz T5 Processors, with 32x 16GB DDR3 DIMMS, no HDD and no I/O cards)
Idle input power
678 W
Peak AC input power (running SpecJBB)
1480 W

Note - The maximum operating input current values are based on the formula P / (V *0.90), where P = maximum operating input power and V = input voltage. For example: 620W / (100V * 0.90) = 6.89A You can use this formula to calculate the maximum operating current at your input voltage.

Caution

Caution  - Use only the power cords provided with the server.