SPARC T5-1B Server Module Installation Guide

Exit Print View

Updated: May 2014
 
 

Plan Communication With the Server Module During Installation

There are several methods to communicate with the server module during the initial installation. Plan which method you will use. Before you perform the installation, arrange to have the equipment, information, and permissions required by that method.


Note - For information about identifying and configuring IP and MAC addresses, refer to the configuring network addresses information in the Servers Administration.
  • Choose one of the connection methods to communicate with the server module SP.

    The connection methods are shown in the figure and described in the table. Obtain the cables, monitoring devices, addresses, and passwords required for the method you choose.


    image:Figure showing the server module.
    Method
    Connection Description
    Connection Requirements
    1
    Ethernet
    From: CMM NET MGT port
    To: Your network
    • Know the IP address of the CMM.

    • Know the CMM Oracle ILOM user and password account information.

    Use one of these procedures based on the type of Oracle ILOM interface you want to use:.
    2
    Serial
    From: Server module SP UCP port
    To: Terminal device
    • A terminal device and serial cable.

    • Dongle cable

    You communicate directly with Oracle ILOM on the server module SP using the CLI. See Power On the Host Through the Front Panel (CLI).
    3
    Serial
    From: CMM SER MGT port
    To: Terminal device
    • A terminal device and serial cable

    • Know the CMM Oracle ILOM user and password account information.

    You communicate through the CMM using the Oracle ILOM CLI. See Power On the Host Through the CMM (CLI).
    .