Environmental Specifications

This topic includes these specifications:

  • Temperature, humidity, and elevation

  • Shock and vibration

Table 1  Temperature, Humidity, and Elevation Specifications
Description
Operating
Nonoperating
Notes
U.S.
Metric
U.S.
Metric
Temperature (maximum)
41 to 95°F at 0 to 2953 ft
5 to 35°C at 900m
-40 to 158°F at 0 to 2953 ft
-40 to 70°C at 900m
Above 2953 ft. (900m), decrease the maximum allowable temperature by 1.6°F per 1000 ft (1°C per 300m).
Relative humidity
10 to 90% at 80.6°F
10 to 90% at 27°C
Up to 93% at 100.4°F
Up to 93% at 38°C
Maximum wet bulb noncondensing.
Altitude
10,000 ft at 95°F
3048m at 40°C
Up to 40,000 ft
Up to 12,000m
Table 2  Shock and Vibration Specifications
Description
Operating
Notes
Shock
3G, 11 ms
Half-sine.
Vibration (vertical)
0.15G
5 to 500 HZ swept-sine.
Vibration (horizontal)
0.10G

Related Information