Install a DIMM

  1. Unpack the replacement DDR4 DIMM and place it on an antistatic mat.
  2. Ensure that the replacement DDR4 DIMM matches the size of the DIMM it is replacing.

    For DIMM socket population rules, see DIMM Population Rules.

  3. Install a DIMM.
    1. Ensure that the ejector tabs are in the open position.
    2. Align the notch in the replacement DIMM with the connector key in the connector socket.

      The notch ensures that the DIMM is oriented correctly.

    3. Push the DDR4 DIMM into the connector socket until the ejector tabs lock the DIMM in place.

      If the DIMM does not easily seat into the connector socket, verify that the notch in the DIMM is aligned with the connector key in the connector socket. If the notch is not aligned, damage to the DIMM might occur.


      image:Figure showing a memory DIMM being installed into the sever.
  4. Repeat Step 3 until all replacement DIMMs are installed.
  5. Return the server to operation:
    1. Lower the air baffle to the installed position.
    2. Install the server top cover.

      See Install the Server Top Cover.

    3. Return the server to the normal rack position.

      See Return the Server to the Normal Rack Position.

    4. Reconnect the power cords and data cables to the server.

      See Reconnect Power and Data Cables.

    5. Power on the server.

      See Power On the Server.

      Verify that the AC OK LED is lit.

  6. (Optional) Use Oracle ILOM to clear server DDR4 DIMM faults.

    DDR4 DIMM faults are automatically cleared after a new memory DIMM has been installed. If you need to manually clear DDR4 DIMM faults, refer to the Oracle Integrated Lights Out Manager (ILOM) 3.2 Documentation Library at: http://www.oracle.com/goto/ilom/docs.