Go to main content

Oracle® Exadata Storage Server X5-2 High Capacity Service Manual

Exit Print View

Updated: January 2018
 
 

System Board Components

The following table lists the system board components.

Component Name (Oracle ILOM CLI Targets)
IPMI Type
Description
Values (if applicable)
/SYS/MB
FRU
General host system board FRU
/SYS/MB/CPLD
FRU
Mainboard CPLD/FPGA firmware version
/SYS/MB/NET[0-3]
FRU
Host Ethernet FRU
/SYS/MB/PCIE[1-6]
FRU
PCIe slot
/SYS/MB/PCIE[1-6]/PRSNT
Discrete sensor
Option card inserted into PCIe slot
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/MB/PCIE3/PCIESW
FRU
PCIe switch for NVMe support, optional, dedicated slot
/SYS/MB/T_OUT_ZONE[0-2]
Threshold sensor
Cooling zone exhaust temperature
Degrees Celsius
/SYS/MB/T_IN_ZONE[0-2]
Threshold sensor
Cooling zone inlet temperature
Degrees Celsius
/SYS/MB/T_CORE_NET01
Threshold sensor
Gigabit Ethernet controller die temperature
CPU 0, NET 0+1 Degrees Celsius
/SYS/MB/T_CORE_NET23
Threshold sensor
Gigabit Ethernet controller die temperature
CPU 1, NET 2+3 Degrees Celsius
/SYS/MB/T_IN_PS
Threshold sensor
PSU inlet temperature
Degrees Celsius
/SYS/SP
FRU
Service processor FRU
/SYS/SP/OK
Indicator
SP OK LED
Color: Green
Location: Front panel
On: SP is operating.
Off: SP requires service.
/SYS/SP/NET[0-1]
FRU
SP Ethernet FRU

Related Information