Operating module old (ADS 48)

The program description deals with the following:

Remarks on program function

The data for connection of a device, type Operating module old can be updated, i.e. programmed, changed or cleared, with this program. Data which has already been stored can also be displayed for information.

When programming the operating module old please ensure that the interface, the processing unit and a keyboard are linked. The operating module old (ADS 48) is connected to the COM A or COM C of the POS board. Use cable 49.100 201 to connect to interface S3 of the ADS 48.

Communications are established after program 05.IMG has been loaded on the ADS 48 (loading path "Floppy Disk"). Then re-start the MICROS Retail OSCAR POS program.

The ADS 48 acts as an operating module after activation of the cashier program.

This implies:


Remarks on data fields

The following description deals with all available options for update of this basic data.

As with nearly all other programs the following applies here:


Descriptor

Entry range permitted: alphanumeric max. 20 chars.

Enter the name of the device in this field. Please ensure that the name assigned is easily identifiable (e.g. op.mod. Com3Proc6 for an operating module which is linked to processing unit 6 and is attached to COM2 of this system unit).


Device interface

Entry range permitted: numeric 1 - 99

Enter the number of the Interface to which this device is/is to be connected. Please ensure that this interface has not already been assigned to another device.

If the number of the interface is not known, the data record can be selected with Search.


Serial no.

Entry range permitted: alphanumeric max. 32 chars.

Enter the serial no. of the device in this field.


Keyboard no.

Entry range permitted: numeric 1 - 9999

Enter the no. of the keyboard which is to be linked to this operating module. A Keyboard must be stored in the system with the appropriate Function key assignment.

If the keyboard no. is not known, the data record can be selected with Search.


Keyboard size

Field with firmly defined selection options

Click onto the option menu to select one of the keyboard sizes available (60, 90, 151, 165).


Debug

Field with firmly defined selection options

Select one of the offered debug levels by clicking onto this field and with a second click confirming the selection.

The system offers the following debug levels:

Note:
Only enter a value higher than "0" for the debug level if a protocol of data communications is required for error analysis. The details are shown in file "errlog" in directory work of the appropriate system unit.


No. of drawers

Field with firmly defined selection options

Select one of the options for the number of drawers by clicking onto this field and with a second click confirming the selection.

The system offers the following drawer counts:


Usage drawer

Field with firmly defined selection options

Enter a value in this field if a drawer is to be connected to this operating module and if this is to open as per the definition in Operator and in the payment type.


Usage display

Field with firmly defined selection options

Select one of the offered options for operating a display by clicking onto this field and with a second click confirming the selection.

The system offers the following operating modes:


Error beep duration

Default = 000 = never ending

The duration of the error beep can be defined in this field. Values between 100 and 25500 milliseconds can be entered.


Scanner

Switch active: A scanner is connected to this operating module
Switch deactivated: No scanner is connected to this operating module


Magnetic cardreader

Switch active: A magnetic card reader is connected to this operating module
Switch deactivated: No magnetic card reader is connected to this operating module


Pen reader

Switch active: A reading pen is connected to this operating module
Switch deactivated: No reading pen is connected to this operating module


Waiter lock

Switch active: A waiter lock is connected to this operating module
Switch deactivated: No waiter lock is connected to this operating module


Operator lock

Switch active: An operator lock is connected to this operating module
Switch deactivated: No operator lock is connected to this operating module


Index


MICROS Retail Deutschland GmbH
Salzufer 8
D-10587 Berlin