Go to main content
SPARC and Netra SPARC S7-2 Series Servers Administration Guide

Exit Print View

Updated: January 2017
 
 

Correlate WWN Device Names With Physical Locations (probe-scsi-all Command)

  1. At the OpenBoot prompt, type:
    ok probe-scsi-all
    /pci@302/pci@2/pci@0/pci@14/LSI,sas@0
    
    FCode Version 1.00.65, MPT Version 2.05, Firmware Version 9.00.00.00
    
    Target 9 
      Unit 0   Disk   HGST     H101860SFSUN600G A3T0    1172123568 Blocks, 600 GB
      SASDeviceName 5000cca02f0256b8  SASAddress 5000cca02f0256b9  PhyNum 0 
    Target a 
      Unit 0   Disk   HGST     H101860SFSUN600G A3T0    1172123568 Blocks, 600 GB
      SASDeviceName 5000cca02f02564c  SASAddress 5000cca02f02564d  PhyNum 1 
    Target b 
      Unit 0   Disk   HGST     H101860SFSUN600G A770    1172123568 Blocks, 600 GB
      SASDeviceName 5000cca02f1390f4  SASAddress 5000cca02f1390f5  PhyNum 2 
    Target c 
      Unit 0   Disk   HGST     H101860SFSUN600G A770    1172123568 Blocks, 600 GB
      SASDeviceName 5000cca02f1376d8  SASAddress 5000cca02f1376d9  PhyNum 3 
    Target d 
      Unit 0   Disk   HGST     H101860SFSUN600G A3T0    1172123568 Blocks, 600 GB
      SASDeviceName 5000cca02f027838  SASAddress 5000cca02f027839  PhyNum 4 
    Target e 
      Unit 0   Disk   HGST     H101860SFSUN600G A3T0    1172123568 Blocks, 600 GB
      SASDeviceName 5000cca02f02e798  SASAddress 5000cca02f02e799  PhyNum 5 
    Target f 
      Unit 0   Disk   HGST     H101860SFSUN600G A3T0    1172123568 Blocks, 600 GB
      SASDeviceName 5000cca02f02b138  SASAddress 5000cca02f02b139  PhyNum 6 
    Target 10 
      Unit 0   Disk   HGST     H101860SFSUN600G A3T0    1172123568 Blocks, 600 GB
      SASDeviceName 5000cca02f028fd0  SASAddress 5000cca02f028fd1  PhyNum 7 
    
    /pci@300/pci@1/pci@0/pci@2/usb@0/storage@1
      Unit 0   Disk     smiMICRON  eUSB DISK       1112
    
    /pci@300/pci@1/pci@0/pci@2/usb@0/hub@2/storage@1
      Unit 0   Removable Read Only device    SUNRemote ISO CDROM1.01
    
  2. In this output, look for these disk identifiers:
    • LSI,sas@0 – Disk controller (a REM in this example). If the server has more than one disk controller, the target drives associated with each controller are listed following that controller's information.

    • SASDeviceName – WWN that Oracle Solaris recognizes.

    • SASAddress – WWN that OpenBoot references.

    • PhyNum – Physical slot that the drive occupies (the value 0 indicates a drive in HDD slot 0).

  3. Look at the values in this output to construct a logical device name in the cntWWNdn format that is recognized by Oracle Solaris.

    For this example, you construct a name like this to indicate the drive in slot 0.

    • cn = c0

      where n is the SAS controller number.

    • tWWN = t5000cca02f0256b8

      where WWN is the SASDeviceName value.

    • dn = d0

      where n is 0 for all embedded SCSI devices.

    The completed logical device name is c0t5000cca02f0256b8d0.

Related Information