Platform Alarms

Platform errors are grouped by category and severity. The categories are listed from most to least severe:

Table 1 shows the alarm numbers and alarm text for all alarms generated by the MPS platform. The order within a category is not significant. Some of the alarms described are not available with specific configurations.

Platform Alarms

Alarm Codes and Error Descriptor

Major Platform Alarms
3000000000000001 – Server fan failure
3000000000000002 - Server Internal Disk Error
3000000000000008 - Server Platform Error
3000000000000010 - Server File System Error
3000000000000020 - Server Platform Process Error
3000000000000080 - Server Swap Space Shortage Failure
3000000000000100 - Server provisioning network error
3000000000001000 - Server Disk Space Shortage Error
3000000000002000 - Server Default Route Network Error
3000000000004000 - Server Temperature Error
3000000000008000 - Server Mainboard Voltage Error
3000000000010000 - Server Power Feed Error
3000000000020000 - Server Disk Health Test Error
3000000000040000 - Server Disk Unavailable Error
3000000000080000 - Device Error
3000000000100000 - Device Interface Error
3000000008000000 - Server HA Keepalive Error
3000000010000000 - DRBD block device can not be mounted
3000000020000000 - DRBD block device is not being replicated to peer
3000000040000000 - DRBD peer needs intervention
3000000400000000 - Multipath device access link problem
3000000800000000 – Switch Link Down Error
3000001000000000 - Half-open Socket Limit
3000002000000000 - Flash Program Failure
3000004000000000 - Serial Mezzanine Unseated
Minor Platform Alarms
5000000000000001 - Server Disk Space Shortage Warning
5000000000000002 - Server Application Process Error
5000000000000004 - Server Hardware Configuration Error
5000000000000008 - Server RAM Shortage Warning
5000000000000020 - Server Swap Space Shortage Warning
5000000000000040 - Server Default Router Not Defined
5000000000000080 – Server temperature warning
5000000000000100 - Server Core File Detected
5000000000000200 - Server NTP Daemon Not Synchronized
5000000000000400 - Server CMOS Battery Voltage Low
5000000000000800 - Server Disk Self Test Warning
5000000000001000 - Device Warning
5000000000002000 - Device Interface Warning
5000000000004000 - Server Reboot Watchdog Initiated
5000000000008000 - Server HA Failover Inhibited
5000000000010000 - Server HA Active To Standby Transition
5000000000020000 - Server HA Standby To Active Transition
5000000000040000 - Platform Health Check Failure
5000000000080000 - NTP Offset Check Failure
5000000000100000 - NTP Stratum Check Failure
5000000000200000 - SAS Presence Sensor Missing
5000000000400000 - SAS Drive Missing
5000000000800000 - DRBD failover busy
5000000001000000 - HP disk resync
5000000020000000 – Server Kernel Dump File Detected
5000000040000000 – TPD Upgrade Failed
5000000080000000 - Half Open Socket Warning Limit