Fan Events
        
            
            
        
        
            
        
        The following table lists fan events.
        
            
            
                
                
                
                    
                         | 
                         | 
                     
                
                
                    
                        | 
                             SNMP Trap:
                                sunHwTrapFanSpeedCritThresholdExceeded 
                            Oracle ILOM Event Message:
                                Lower critical threshold exceeded 
                            Severity and Description:
                                Major; A fan speed sensor has reported that its value has gone above
                                an upper critical threshold setting or below a lower critical
                                threshold setting. 
                            The sunHwTrapThresholdType object indicates whether the threshold
                                was an upper or lower threshold. 
                         | 
                        
                             /SYS/MB/FM[0-3]/F[0-x]/TACH 
                         | 
                     
                    
                        | 
                             SNMP Trap:
                                sunHwTrapFanSpeedCritThresholdDeasserted 
                            Oracle ILOM Event Message:
                                Lower critical threshold no longer exceeded 
                            Severity and Description:
                                Informational; A fan speed sensor has reported that its
                                value has gone below an upper critical threshold setting or above a
                                lower critical threshold setting. 
                            The sunHwTrapThresholdType object indicates whether the threshold
                                was an upper or lower threshold. 
                         | 
                        
                             /SYS/MB/FM[0-3]/F[0-x]/TACH 
                         | 
                     
                    
                        | 
                             SNMP Trap:
                                sunHwTrapFanSpeedFatalThresholdExceeded 
                            Oracle ILOM Event Message:
                                Lower fatal threshold exceeded 
                            Severity and Description:
                                Critical; A fan speed sensor has reported that its value has gone
                                above an upper fatal threshold setting or below a lower fatal
                                threshold setting. 
                            The sunHwTrapThresholdType object indicates whether the threshold
                                was an upper or lower threshold. 
                         | 
                        
                             /SYS/MB/FM[0-3]/F[0-x]/TACH 
                         | 
                     
                    
                        | 
                             SNMP Trap:
                                sunHwTrapFanSpeedFatalThresholdDeasserted 
                            Oracle ILOM Event Message:
                                Lower fatal threshold no longer exceeded 
                            Severity and Description:
                                Informational; A fan speed sensor has reported that its value has
                                gone below an upper fatal threshold setting or above a lower fatal
                                threshold setting. 
                            The sunHwTrapThresholdType object indicates whether the threshold
                                was an upper or lower threshold. 
                         | 
                        
                             /SYS/MB/FM[0-3]/F[0-x]/TACH 
                         | 
                     
                
              |