Install the Power, FIM, Temperature Sensor, and Disk Backplane Data Cables

  1. Install the disk backplane data cable.
    1. Connect the disk backplane data cable to the motherboard by opening both side latches and plugging the data cable connector into the motherboard connector [8].

      The motherboard connector side latches will close, locking the disk backplane data cable connector in place.

    2. Connect the disk backplane data cable to the disk backplane by opening both side latches and plugging the data cable connector into the disk backplane connector [7].

      The disk backplane connector side latches will close, locking the disk backplane data cable connector in place.

  2. Install the FIM cable.
    1. Install the FIM cable into the motherboard by opening both side latches and plugging the FIM connector into the motherboard connector [6].

      The motherboard connector side latches will close, locking the FIM cable connector in place.

    2. Connect the FIM cable to the FIM by plugging the cable connector into the FIM [5].
    3. Install the FIM into the server.

      See Install the Front LED Indicator Module.

  3. Install the temperature sensor cable.
    1. Route the temperature sensor cable through the left-front chassis sidewall and install the sensor into the FIM housing [4].
    2. Connect the temperature sensor cable to the disk backplane by plugging the cable connector into the disk backplane connector [3].
    3. Install the FIM into the server.

      See Install the Temperature Sensor.

  4. Install the disk backplane power cable.
    1. Connect the disk backplane power cable to the disk backplane by plugging the cable connector into the disk backplane connector [2].
    2. Connect the disk backplane power cable to the motherboard by plugging the cable connector into the motherboard connector [1].
  5. Return the server to operation.
    1. Install the server top cover.

      See Install the Server Top Cover.

    2. Return the server to the normal rack position.

      See Return the Server to the Normal Rack Position.

    3. Reconnect the power cords to the power supplies, and power on the server.

      See Reconnect Data Cables and Power Cords and Power On the Server.

    4. Verify that the System OK status indicator is lit.