Go to main content

Oracle® Server X7-2 Service Manual

Exit Print View

Updated: January 2021
 
 

System Motherboard Components

The following table lists the system motherboard components.

Component Name (Oracle ILOM CLI Targets)
IPMI Type
Description
Values (if applicable)
/SYS/MB
FRU
General host system motherboard FRU
/SYS/MB/CPLD
FRU
Motherboard CPLD/FPGA firmware version
/SYS/MB/NET[0-x]
FRU
Host Ethernet FRU
/SYS/MB/RISER[1-x]/PCIE[1-x]
FRU
PCIe slot
/SYS/MB/RISER[1-x]/PCIE[1-x]/PRSNT
Discrete sensor
PCIe slot is occupied.
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/MB/T_OUT_SLOT[1-3]
Threshold sensor
Cooling zone chassis exhaust temperature, located behind the specified PCIe slots
  • Slot 1 – PCIe slot 1

  • Slot 2 – PCIe slot 2

  • Slot 3 – PCIe slot 3

Degrees Celsius
/SYS/MB/T_IN_SLOT[1-3]
Threshold sensor
Cooling zone chassis inlet temperature, located in front of the specified PCIe slots
  • Slot 1 – PCIe slot 1

  • Slot 2 – PCIe slot 2

  • Slot 3 – PCIe slot 3

Degrees Celsius
/SYS/SP
FRU
Service processor FRU
/SYS/SP/OK
Indicator
SP OK LED
Color: Green
Location: Front panel
On: SP is operating.
Off: SP requires service.
/SYS/SP/NET[0-1]
FRU
SP Ethernet FRU
/SYS/MB/RISER3
FRU
M.2 SSD riser
/SYS/MB/RISER3/PRSNT
Discrete sensor
M.2 riser presence
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/MB/RISER3/SSD[0-1]
FRU
Internal M.2 SSD drives
/SYS/MB/RISER3/SSD[0-1]/PRSNT
Discrete sensor
M.2 SSD drive presence
01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/MB/RISER3/SSD[0-1]/STATE
State sensor
M.2 SSD drive state sensor
04h-INSTALLED
20h-SLOT_POWER_OFF

Related Information