Environmental Events
The following table lists environmental events.
|
|
SNMP Trap:
sunHwTrapTempFatalThresholdExceeded
Oracle ILOM Event Message:
Lower fatal threshold exceeded
Severity and Description:
Critical; A temperature sensor reported that its value went above an
upper fatal threshold setting or below a lower fatal threshold
setting.
The sunHwTrapThresholdType object indicates whether the threshold
was an upper or lower threshold.
|
/SYS/PS[0-1]/T_OUT
/SYS/PS[0-1]/T_IN
/SYS/MB/T_IN_ZONE[0-2]
/SYS/MB/T_OUT_ZONE[0-2]
|
SNMP Trap:
sunHwTrapTempFatalThresholdDeasserted
Oracle ILOM Event Message:
Lower fatal threshold no longer exceeded
Severity and Description:
Informational; A temperature sensor reported that its value went
below an upper fatal threshold setting or above a lower fatal
threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold
was an upper or lower threshold.
|
/SYS/PS[0-1]/T_OUT
/SYS/PS[0-1]/T_IN
/SYS/MB/T_IN_ZONE[0-2]
/SYS/MB/T_OUT_ZONE[0-2]
|
SNMP Trap:
sunHwTrapTempCritThresholdExceeded
Oracle ILOM Event Message:
Upper critical threshold exceeded
Severity and Description:
Critical; A temperature sensor reported that its value went above an
upper critical threshold setting or below a lower critical threshold
setting.
The sunHwTrapThresholdType object indicates whether the threshold
was an upper or lower threshold.
|
/SYS/PS[0-1]/T_OUT
/SYS/PS[0-1]/T_IN
/SYS/MB/T_IN_ZONE[0-2]
/SYS/MB/T_OUT_ZONE[0-2]
|
SNMP Trap:
sunHwTrapTempCritThresholdDeasserted
Oracle ILOM Event Message:
Upper critical threshold no longer exceeded
Severity and Description:
Informational; A temperature sensor reported that its value went
below an upper critical threshold setting or above a lower critical
threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold
was an upper or lower threshold.
|
/SYS/PS[0-1]/T_OUT
/SYS/PS[0-1]/T_IN
/SYS/MB/T_IN_ZONE[0-2]
/SYS/MB/T_OUT_ZONE[0-2]
|
SNMP Trap:
sunHwTrapTempFatalThresholdExceeded
Oracle ILOM Event Message:
Lower fatal threshold exceeded
Severity and Description:
Critical; A temperature sensor reported that its value went above an
upper fatal threshold setting or below a lower fatal threshold
setting.
The sunHwTrapThresholdType object indicates whether the threshold
was an upper or lower threshold.
|
/SYS/T_AMB
|
SNMP Trap:
sunHwTrapTempFatalThresholdDeasserted
Oracle ILOM Event Message:
Lower fatal threshold no longer exceeded
Severity and Description:
Informational; A temperature sensor reported that its value went
below an upper fatal threshold setting or above a lower fatal
threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold
was an upper or lower threshold.
|
/SYS/T_AMB
|
|