Install a PCIe Card or Filler


Caution

Caution  -  This procedure requires that you handle components that are sensitive to ESD which can cause server components to fail.


  1. Take the necessary ESD precautions.

    See Prevent ESD Damage.

  2. Ensure that the server is powered off and all power cords are disconnected from the server power supplies.

    See Removing Power From the Server.

  3. Determine which slot to install the PCIe card in.

    If you are not replacing an existing PCIe card and need information about deciding which slot to install the card in, see PCIe Card Configuration.

  4. Disengage the PCIe card slot crossbar from its locked position by pulling it toward the interior of the chassis.

    The crossbar might already be disengaged if you removed a PCIe card or filler from that slot.

  5. Install the PCIe card or filler into the card slot and return the crossbar to its closed and locked position.
    • See these figures if you are installing a PCIe card.
      image:Figure showing how to install a PCIe card.
    • See these figures if you are installing a PCIe card filler.
      image:Figure showing how to install a PCIe card filler.
  6. Return the server to operation.

    See Returning the Server to Operation.

  7. Verify that the card is properly installed.

    See Verify a PCIe Card.

  8. Configure the PCIe card.

    Refer to the documentation shipped with the PCIe card for information about configuring the PCIe card, including installing required operating systems.