Go to main content

Oracle® VM Server for SPARC 3.5 Administration Guide

Exit Print View

Updated: November 2017
 
 

Configuring and Using IPMP in the Service Domain

On an Oracle Solaris 11 system, you can configure IPMP in a service domain by configuring physical interfaces into a group in the same way as on a system that has no virtual network or domains. On an Oracle Solaris 10 system, you can configure IPMP in the service domain by configuring virtual switch interfaces into a group. Two Physical NICs Configured as Part of an IPMP Group (Oracle Solaris 11) and Two Virtual Switch Interfaces Configured as Part of an IPMP Group (Oracle Solaris 10) show two virtual switch instances (vsw0 and vsw1) that are bound to two different physical devices. The two virtual switch interfaces can then be created and configured into an IPMP group. In the event of a physical link failure, the virtual switch device that is bound to that physical device detects the link failure. Then, the virtual switch device sends notification of this link event to the IP layer in the service domain, which results in a failover to the other virtual switch device in the IPMP group. The two physical interfaces are net0 and net1 in Oracle Solaris 11 and nxge0 and nxge1 in Oracle Solaris 10.

Figure 21  Two Physical NICs Configured as Part of an IPMP Group (Oracle Solaris 11)

image:Shows how two physical NICs are configured as part of an IPMP group as described in the text.

Figure 22  Two Virtual Switch Interfaces Configured as Part of an IPMP Group (Oracle Solaris 10)

image:Shows how two virtual switch interfaces are configured as part of an IPMP group as described in the text.