Go to main content

Oracle® VM Server for SPARC 3.5 Administration Guide

Exit Print View

Updated: November 2017
 
 

How to Re-Enable the ILOM Interconnect Service

The ilomconfig-interconnect service is enabled by default. Use this procedure if you need to re-enable this service manually.

  1. Enable the ILOM interconnect service.
    primary# svcadm enable ilomconfig-interconnect
  2. Verify that the ilomconfig-interconnect service is enabled.
    primary# svcs ilomconfig-interconnect
    STATE          STIME    FMRI
    online          9:53:28 svc:/network/ilomconfig-interconnect:default
  3. Verify that the ILOM interconnect is configured properly.

    A proper ILOM interconnect configuration shows the State value as enabled and the Host Interconnect IP Address value as an IP address and not none.

    primary# ilomconfig list interconnect
    Interconnect
    ============
    State: enabled
    Type: USB Ethernet
    SP Interconnect IP Address: 169.254.182.76
    Host Interconnect IP Address: 169.254.182.77
    Interconnect Netmask: 255.255.255.0
    SP Interconnect MAC Address: 02:21:28:57:47:16
    Host Interconnect MAC Address: 02:21:28:57:47:17
  4. Verify that the ldmd daemon can communicate with the SP.
    primary# ldm list-spconfig