Skip Navigation Links | |
Exit Print View | |
![]() |
Sun Fire X4800 Server Diagnostics Guide Sun Fire X4800 Server Documentation |
About This Documentation (PDF and HTML)
Overview of the Diagnostics Guide
Introduction to System Diagnostics
How to Gather Service Visit Information
How to Troubleshoot Power Problems
How to Externally Inspect the Server
How to Internally Inspect the Server
Identifying DIMM Error Messages
How BIOS POST Memory Testing Works
How to Isolate and Correct DIMM ECC Errors
Default BIOS Power-On Self-Test (POST) Events
Using the ILOM to Monitor the Host
Viewing the ILOM Sensor Readings
Viewing the ILOM System Event Log
Interpreting Event Log Time Stamps
Creating a Data Collector Snapshot
How to Create a Snapshot With the ILOM Web Interface
How to Create a Snapshot With the ILOM Command-Line Interface
Using SunVTS Diagnostics Software
Introduction to SunVTS Diagnostic Test Suite
How to Diagnose Server Problems With the Bootable Diagnostics CD
Performing Pc-Check Diagnostic Tests
See the following example:
Event# | Date | Time | Memory | Uncorrectable Error |Asserted | OEM Data-2 0x12 OEM Data-3 0x9d
The Data Byte 2 field contains the following information:
Bits 6-7 = 00b Indicates data is for ECC Memory Error
Bits 4-5 = Branch Memory Branch ID
Bits 0-3 = CPU # Node Number (CPU Package Number)
The Data Byte 3 field contains the following information:
Bits 4-7 = DIMM 0 of pair
Bits 0-3 = DIMM 1 of pair
In above example:
Data-2: 0x12 = 0001,0010 binary = Branch 1 , CPU 2
Data-3: 0x9d = DIMM9, DIMM13