Event Log Messages Might Be Out of Sequence and Duplicated (CR 6915976)

Messages in the event log might be out of sequence and duplicated. For example:

14     Fri Apr 16 05:42:50 2010  IPMI      Log       critical
       ID =    a : 04/16/2010 : 05:42:50 : System Firmware Progress : BIOS : Man
       agement controller initialization
13     Fri Apr 16 05:42:49 2010  IPMI      Log       critical
       ID =    9 : 04/16/2010 : 05:42:49 : System Boot Initiated : BIOS : Initia
       ted by hard reset
12     Fri Apr 16 05:42:48 2010  IPMI      Log       critical
       ID =    a : 04/16/2010 : 05:43:54 : Button : sensor number = 0x00 : Power
        Button pressed
11     Fri Apr 16 05:42:47 2010  IPMI      Log       critical
       ID =    8 : 04/16/2010 : 05:42:47 : Module/Board : BL3/STATE : Transition
        to Running
10     Fri Apr 16 05:35:36 2010  IPMI      Log       critical
       ID =    7 : 04/16/2010 : 05:35:36 : Entity Presence : BL0/FMOD1/PRSNT : D
       evice Absent
9      Fri Apr 16 05:35:27 2010  IPMI      Log       critical
       ID =    6 : 04/16/2010 : 05:35:27 : Module/Board : BL0/STATE : Transition
        to Power Off

Note message number 12; its ID should be 8, and the IDs of subsequent messages should be decremented accordingly.