Index

Symbols

(, 1

Numerics

64 LUNs in redundant point-to-point configurations, 1

A

active-active configuration, 1

active-standby configuration, 1

add drive Entry command, 1

Add Global spare drive command, 1

add Local spare drive command, 1

add SCSI drives command, 1

adding

drive entry, 1

global spare drive, 1

local spare drive, 1

SCSI drives, 1

Adding a Host ID, 1

Adding or Deleting Drive Entries, 1

alarms silencing, 1

Assigning a Local Spare Drive, 1

automatic rebuild, 1

B

BAD drive status, 1

battery

period of usage, 1

shelf life, 1

Battery Operation, 1

battery support, 1

beeper muting, 1

Before You Begin, 1

bus configurations, 1

C

cabling

single- and dual-bus configurations, 1

cache parameters, 1

cache status, 1

Changing a Logical Drive Controller Assignment, 1

channel IDs

permanent, 1

channel status, 1

channels

configuring as host or drive, 1

check time

periodic auto-detection of failed drive swap, 1

Clear drive status command, 1

clone failing drive, 1

perpetual clone, 1

Cloning a Failing Drive, 1

COM port

connecting, 1

concurrent rebuild, 1

configuration

minimum requirements, 1

restoring from a file, 1

saving to a file, 1, 2

Configuring SCSI Channels as Host or Drive, 1

controller

muting beeper, 1

name, 1, 2

naming, 1, 2

optimization mode, 1

parameters, 1

password validation timeout, 1

SDRAM ECC, 1

unique identifier, 1

resetting, 1

restoring your configuration, 1

saving your configuration, 1, 2

shutting down, 1

controller assignment, 1

Controller Failover, 1

controller failure, 1

controller limitations, 1

controller NAME, 1

Controller Parameters, 1

Controller Parameters command, 1

Controller Voltage and Temperature Status, 1

copy and replace

logical drive, 1

copy and replace drive command, 1

create

logical drive, 1

creating

logical volume, 1

Creating a Global Spare, 1

Creating a Logical Volume, 1

Creating Additional Host IDs, 1

Creating Host Filter Entries, 1

Creating Logical Drives, 1

cylinder/head/sector mapping, 1

D

Default Fibre Channel Host IDs, 1

Default SCSI Host IDs, 1

defaults

drive-swap check time, 1

enable UPS status, 1

host LUN connections, 1

logical drives, 1

number of LUNs per host SCSI ID, 1

password validation, 1

RAID levels, 1

SDRAM ECC, 1

UPS alert notification level, 1

Define Peripheral Device Active Signal command, 1

Delete global/local spare drive command, 1

deleting

drive entries, 1

host channel SCSI ID, 1

partition of logical drive

caution, 1

SCSI drive table

slot number, 1

SCSI ID, 1

spare drive, 1

Deleting a Host LUN Mapping, 1

deleting a logical drive, 1

Deleting a Logical Drive Partition, 1

Deleting a Spare Drive, 1

Determining the Host Worldwide Name, 1

DHCP, 1

disconnecting support, 1

SCSI target/drive channel, 1

disk

access delay time, 1

array parameters

advanced config, 1

drive

cloning a failing, 1

entries

adding, 1

deleting, 1

failed, 1

checking, 1

partitioning a logical, 1

spare, 1

spares

global, 1

local, 1

drive channel

viewing and editing targets, 1

drive entries

adding or deleting, 1

drive failure

recovering from fatal, 1

drive information

viewing, 1

drive status, 1

drives

creating logical, 1

drive-side parameters

advanced config, 1

DRV FAILED status, 1

dual-bus configurations, 1

Dynamic Host Configuration Protocol, 1

E

ECC SDRAM function, 1

editing logical drives, 1

Enabling and Disabling Write-Back and Write-Through Cache, 1

error statistics, FC, 1

Execute Drive Testing command, 1

Expand logical drive command, 1

Expand logical volume command, 1

expanding

limitations, 1

logical drive, 1

copy and replace, 1

logical volume, 1, 2

expansion

limitations, 1

F

failed drive

identifying a, 1

failing drive

cloning, 1

failover

controller, 1

fatal drive failure

recovering from, 1

fault management, controller parameters, 1

fault prevention, 1

FC arrays

planning for 1024 LUNs on, 1

FC channel error statistics, 1

fibre channel

controller parameter settings, 1

Fibre Connection Option, 1

filter

host, 1

filter entries

creating host, 1

filtering

LUN, 1

firmware

automatic rebuild, 1

initial window, 1

logical drive status, 1, 2

main menu, 1

manual rebuild, 1

navigation keys, 1

quick installation, 1

SCSI drive status, 1

upgrading, 1

view event logs, 1

firmware download

considerations, 1

firmware window

initial screen, 1

viewing, 1

Flash All Drives command, 1

flash drive time command, 1

flashing

all SCSI drives, 1

format

low-level, 1

G

gauge range, 1

global spare drive, 1, 2

creating, 1

deleting, 1

explained, 1

H

head

mapping, 1

host application, 1

host channel SCSI ID

adding, 1

deleting, 1

Host Cylinder/Head/Sector Mapping Configuration command, 1

Host Filter Entries, 1

host filter entries

creating, 1

host ID

adding, 1

host IDs

creating, 1

default Fibre Channel, 1

default SCSI, 1

host LUN

connection

number of tags reserved, 1

example mappings, 1

host LUN connections, 1

host LUN mapping

deleting a, 1

host LUNs

mapping logical drive partitions to, 1

host worldwide name

determining, 1

host-side parameters, 1

I

I/O

maximum queued count, 1

SCSI timeout, 1

ID

SCSI, deleting, 1

Identifying a Failed Drive for Replacement, 1

identifying drives, 1, 2

Identifying SCSI drive command, 1

INCOMPLETE status, 1

initial firmware window, 1

initial screen

main menu, 1

INITING status, 1

INVALID status, 1

K

keys to navigate, 1

L

LCD title display controller name

not applicable, 1

limitations

controller, 1

expanding, 1

logical volume, 1

local spare assignment, 1

local spare drive, 1

assigning, 1

definition, 1

local spare drives

deleting, 1

explained, 1

logical drive

128 LUN limit, 1

128-LUN limit, 1

adding a SCSI drive, 1

assign local spare, 1

assigning a name, 1

change assignment, 1

commands, 1

view and edit logical drives, 1, 2

copying and replacing, 1

creating, 1, 2, 3

defaults, 1

deleting, 1

drive allocation, 1

expanding, 1

explained, 1

ID, 1

larger than 253 Gbyte, 1, 2

LG number, 1

maximum number of disks per logical drive, 1

maximum physical capacity, 1

maximum usable capacity per logical drive, 1

minimum requirements, 1

parity

checking, 1, 2

partitioning, 1

RAID level, 1

RAID level selected, 1

RAID levels, 1

rebuilding, 1

size, 1

status, 1

viewing and editing, 1

logical drive name

changing, 1

creating, 1

logical drive partition

deleting, 1

logical drive partitions

mapping to host LUNs, 1

logical drives, 1

creating, 1

rebuilding, 1

logical volume, 1, 2, 3

avoiding failure, 1

creating, 1, 2

expanding, 1

using RAID expansion, 1

explained, 1, 2

limitations, 1

maximum partitions, 1

partitioning, 1

spare drives, 1

logical volume status table, 1

loop only, 1

loop preferred, 1

loopback error statistics, 1

low-level format, 1

LUN

described, 1

mapping a partition to, 1

per host SCSI ID, 1

changing, 1

LUN filtering, 1

LUN mapping

deleting a, 1

LUNs

mapping logical drive partitions to, 1

maximum in point-to-point configurations, 1

planning for 1024 on FC arrays, 1

planning for 128 on SCSI arrays, 1

M

Main Menu, 1

manual rebuild, 1

mapping

cylinder/head/sector, 1

Mapping a Partition to a LUN, 1

Mapping Logical Drive Partitions to Host LUNs, 1

maximum

queued I/O count, 1

tag count (tag command queuing), 1

transfer width, 1

maximum concurrent host LUN connections, 1

maximum drive capacity, 1

Maximum Queued I/O Count command, 1

maximum sync. xfer Clock command, 1

Maximum Tag Count (tag command queuing) command, 1

maximum xfer Width command, 1

MISSING drive status, 1

motor spin-up, 1

SCSI, 1

muting alarms, 1

muting beeper, 1

N

NAME (controller), 1

naming

controller, 1, 2

NEW DRV drive status, 1

nexus (SCSI), 1

non-volatile RAM

restoring your configuration from a file, 1

saving your configuration to a file, 1, 2

Number of Tags Reserved for each Host-LUN Connection Command, 1

NVRAM

restoring your configuration from a file, 1

saving your configuration to a file, 1, 2

O

optimization

random I/O

maximum size, 1

sequential I/O

maximum size, 1

optimization mode, 1

limitations, 1

random or sequential, 1

P

parameters

cache, 1

controller, 1

drive-side, 1

host-side

advanced config, 1

physical drives, 1

parity

logical drive

checking, 1, 2

parity check, 1, 2, 3

SCSI target/drive channel, 1

partition

deleting a logical drive, 1

mapping to a LUN, 1

partitioning

logical volume, 1

Partitioning a Logical Drive, 1

partitions

logical volume

maximum, 1

mapping logical drive to host LUNs, 1

password

disabling, 1

setting a new, 1

setting new, 1

validation timeout, 1

Password Validation Timeout command, 1

PBCs, 1

periodic drive check time, 1

periodic drive swap auto check, 1

peripheral device

setting, 1

viewing SAF-TE status, 1

viewing status, 1

Permanent SCSI Drive Channel IDs, 1

perpetual clone

clone failing drive, 1

Physical Drive Status Table, 1

physical drives

parameters, 1

physical drives listed, 1, 2

Planning for 1024 LUNs on FC Arrays, 1

Planning for 128 LUNs on SCSI Arrays, 1

Planning for 64 LUNs in Redundant FC Point-to-Point Configurations, 1

point to point only, 1

point to point preferred, 1

point-to-point configurations

maximum LUNs, 1

port bypass circuit, 1

preparing for logical drives larger than 253 Gbyte, 1, 2

primary/secondary controller ID, 1

Q

quick installation, 1

warning, 1

R

RAID

advantages, 1

controller, 1

multilevel, 1

planning considerations, 1

RAID (5+0), 1

RAID (5+1), 1

RAID (5+5), 1

RAID 1+0, 1

concurrent rebuild in, 1

RAID Levels, 1

RAID levels

controller optimization mode, 1

described, 1

planning, 1

RAID 0, 1

RAID 1, 1

RAID 1+0, 1

RAID 3, 1

RAID 3+0, 1

RAID 5, 1

RAID 5+0, 1

range of disks/logical drives supported, 1

selected, 1

RAID Terminology Overview, 1

random I/O optimization

maximum size, 1

RARP, 1

Read/Write Test, 1

rebuild

automatic, 1

concurrent in RAID 1+0, 1

manual, 1

Rebuild logical drive command, 1

Rebuild Priority command, 1

rebuilding, 1

logical drive, 1

Rebuilding Logical Drives, 1

Recovering From Fatal Drive Failure, 1

redundant controller

explained, 1

Regenerate Parity command, 1

replace after clone

clone failing drive, 1

Replace After Clone command, 1

reset button

silencing failed component alarms, 1

Restoring Your Configuration (NVRAM) From a File, 1

RS-232

connecting to, 1

S

SAF-TE status

viewing peripheral device, 1

Saving Your Configuration (NVRAM) to a File, 1, 2

SB-MISS drive status, 1

scanning

new SCSI drive, 1

scanning a new SCSI drive, 1

Scanning Drives, 1

SCSI

channel

status, 1

terminator, 1

I/O timeout, 1

ID

deleting, 1

motor spin-up, 1

reset at power-up, 1

transfer clock speed

setting, 1

SCSI channel

setting termination, 1

SCSI Channel Status Table, 1

SCSI drive

adding to a logical drive, 1

disk capacity, 1

fibre port name, 1

global or local spare, 1

low-level format, 1

read/write test, 1

redundant loop ID, 1

revision number, 1

scanning new, 1

serial number, 1

setting slot numbers, 1

slot number

deleting, 1

STANDBY mode, 1

table

adding entries, 1

clear drive status, 1

deleting drive entries, 1

USED DRV mode, 1

utilities, 1, 2

vendor ID, 1

viewing information, 1

scsi Drive Low-Level Format command, 1

SCSI drive status, 1

SCSI Drive Utilities, 1

SCSI Motor Spin-Up command, 1

SCSI target drive channel

viewing and editing, 1

SCSI target/drive channel

parity check, 1

slot number, 1

scsi Terminator command, 1

SDRAM ECC, 1

default, 1

sector

mapping, 1

sequential I/O optimization

maximum size, 1

serial port

connecting, 1

connection and setup, 1

serial port parameters, 1

SES status

viewing, 1

set slot Number command, 1

setting a new password, 1

Setting a SCSI Channel Termination, 1

Setting Peripheral Device Entry, 1

Setting Slot Numbers, 1

Setting the SCSI Transfer Width, 1

Setting the UPS Power Fail Signal, 1

Setting Transfer Clock Speed, 1

Setting Up the Serial Port Connection, 1

silencing alarms, 1

single-bus configurations, 1

slot number

assigning to empty slot, 1

deleting, 1

SCSI target/drive, 1

setting, 1

slot numbers

setting, 1

spare (local for logical drive), 1

spare drive

assigning a local, 1

creating a global, 1

deleting, 1

spare drives, 1, 2

deleting, 1

global, 1

creating, 1

local, 1

explained, 1

logical volume, 1

STAND-BY drive status, 1

status

drive, 1

logical drive, 1

peripheral device, 1

UPS, 1

status table

logical volume, 1

sync transfer clock, 1

system functions

controller

resetting, 1

shutting down, 1

password

disabling, 1

setting new password, 1

T

tag count

maximum, 1

temperature status

controller, 1

terminator

SCSI channel, 1

transfer clock

maximum synchronous, 1

transfer clock speed

setting, 1

transfer rate indicator, 1

transfer width

maximum, 1

setting, 1

U

uninterruptible power supply

enable status, 1

Upgrading Firmware, 1

UPS

enable status, 1

fail signal, 1

status, 1

UPS power fail signal, 1

setting, 1

USED DRV drive status, 1

utilities

SCSI drive, 1

V

Verification on LD Initialization Writes Disabled command, 1

verification on writes, 1

view

connected drives, 1, 2

view and edit host LUNs command, 1

view and edit logical drives command, 1, 2

view and edit logical Volumes command, 1

view and edit scsi drives command, 1

view peripheral device status command, 1

Viewing and Editing Drive Channel SCSI Targets, 1

Viewing Drive Information, 1

viewing logical drives, 1

Viewing Peripheral Device Controller Status, 1

Viewing Peripheral Device SAF-TE Status, 1

Viewing SES Status, 1

Viewing the Connected Drives, 1

Viewing the Initial Firmware Windows, 1

voltage status

controller, 1

VT-100

connection and setup, 1

W

warnings

quick installation, 1

write error

avoiding, 1

write-back cache

disabling, 1

enabling, 1

write-through

disabling, 1

enabling, 1