Oracle Solaris
10 8/11 Required Patches
Before installing Oracle Solaris 10 8/11 on the server, you
should install the patches listed in the following table.
Table 1 Required Patches for Oracle Solaris 10 8/11
|
|
|
150401-12
|
16353003
|
ILOM Remote Console issue. When using the Oracle ILOM Remote
Console (eeprom variable "console" set to "text") the system
could appear to hang in the final stages of halting.
|
150401-09
|
15786729
|
BIOS issue. Patch fixes issue with power limit.
|
145649-04
|
15829089
|
Driver issue. Patch fixes issue with crash dump during
poweroff with qlge driver installed.
|
150631-04
|
15805238
|
Installation issue. Patch fixes intermittent install
crash.
|
148170-02
|
7097919
|
Ethernet issue. This patch fixes an issue with Ethernet
(ixgbe) ports losing link. Note that this issue also affects
Oracle Solaris JumpStart installations. To support JumpStart
installations, apply this patch to your Oracle Solaris 10 8/11
JumpStart miniroot image. The instructions for patching miniroot
are in the Oracle Solaris 10 8/11
Installation Guide: Network Based Installations,
which is available at this web site: https://docs.oracle.com/cd/E23823_01/html/E23800/netinstall-patch.html
|
147706-02
|
6986256
|
FMA support. This patch adds support for Oracle Solaris Fault
Management Architecture (FMA) for the Intel processor (CPU) used
in the Sun Server X3-2L.
|
148172-01
|
6893274
|
Kernel issue. This patch fixes a problem with delayed
visibility to processor threads that can cause a panic that
contains the string turnstile_block and
unowned mutex.
|
147441-08
|
7001739
|
AVX issue. This patch fixes an issue with Intel AVX
support.
|
147156-01
|
6956660
|
Processor (CPU) performance counters support. This patch adds
performance counter support for the Intel processor used in the
Sun Server X3-2L.
|
147150-01
|
7052663
|
HBA issue. This patch fixes a panic that can occur when
booting from an SGX-SAS6-INT-Z host bus adapter (HBA).
|
148099-03
|
7026372
|
SCSI issue. This patch fixes an issue with SCSI DMA transfers
during cable disconnects that reports "Error setting up next
portion of DMA transfer".
|
|