Go to main content
Sun Flash Accelerator F80 PCIe Card User's Guide

Exit Print View

Updated: December 2013
 
 

Health Reporting Command

The -health command shows the overall health status of a selected card and its components. If any alert exists, this command shows the component that is causing the alert, along with further information. Use the -health command to verify firmware versions before and after firmware updates.

Text Menu Interface Usage: The following top-level menu lists the cards in the system and prompts you to select a card on which to perform an operation. Four Sun Flash Accelerator F80 PCIe Cards are shown in the following example:

# ddcli

ID    WarpDrive     Package Version    PCI Address
--    ---------     ---------------    -----------
1     ELP-4x200-4d-n    09.05.24.00        00:02:00:00
2     ELP-4x200-4d-n    09.05.24.00        00:03:00:00
3     ELP-4x200-4d-n    09.05.24.00        00:04:00:00
4     ELP-4x200-4d-n    09.05.24.00        00:05:00:00
Select the WarpDrive [1-4 or 0:Quit]: 1
1.    List WarpDrive Information
2.    Update Flash Package
3.    Display WarpDrive Health
4.    Locate WarpDrive
5.    Format WarpDrive
6.    Show Vital Product Data
7.    Extract SMART Logs

Select Operation [1-7 or 0:Quit]: 3

Command Line Interface Usage: Enter the following line of text in the CLI to run the -health command: ddcli -c1 -health

Sample Output: When the -health command runs, the ddcli utility outputs the following text.

# ddcli -health
****************************************************************************
   LSI Corporation WarpDrive Management Utility
   Version 110.110.03.00 (2013.07.12)
   Copyright (c) 2013 LSI Corporation. All Rights Reserved.
****************************************************************************

Raid Volume status = unconfigured.
--------------------------------
WarpDrive ELP-4x200-4d-n Health
--------------------------------

Backup Rail Monitor          : GOOD




SSD Drive SMART Data Slot #: 4: Drive Serial Number 11000082150        

-------------- Current (since last Power Cycle)  ----------------------
Current Temperature                   36         (degree C)

-------------- Cumulative  --------------------------------------------
Retired Block Count                   0        
Power-On Hours                        184.2    
Uncorrectable RAISE Errors            0        
Maximum Lifetime Temperature          55         (degree C)
SSD Life Left (PE Cycles)             100        (%)
Total Writes From Host                10954    
Total Reads To Host                   8996     
Warranty Remaining                    100        (%)

Life left                          : 100.000


SSD Drive SMART Data Slot #: 5: Drive Serial Number 11000082614        

-------------- Current (since last Power Cycle)  ----------------------
Current Temperature                   37         (degree C)

-------------- Cumulative  --------------------------------------------
Retired Block Count                   0        
Power-On Hours                        184.3    
Uncorrectable RAISE Errors            0        
Maximum Lifetime Temperature          55         (degree C)
SSD Life Left (PE Cycles)             100        (%)
Total Writes From Host                11045    
Total Reads To Host                   9016     
Warranty Remaining                    100        (%)

Life left                          : 100.000


SSD Drive SMART Data Slot #: 6: Drive Serial Number 11000081523        

-------------- Current (since last Power Cycle)  ----------------------
Current Temperature                   36         (degree C)

-------------- Cumulative  --------------------------------------------
Retired Block Count                   0        
Power-On Hours                        184.3    
Uncorrectable RAISE Errors            0        
Maximum Lifetime Temperature          61         (degree C)
SSD Life Left (PE Cycles)             100        (%)
Total Writes From Host                11053    
Total Reads To Host                   8997     
Warranty Remaining                    100        (%)

Life left                          : 100.000


SSD Drive SMART Data Slot #: 7: Drive Serial Number 11000082494        

-------------- Current (since last Power Cycle)  ----------------------
Current Temperature                   37         (degree C)

-------------- Cumulative  --------------------------------------------
Retired Block Count                   0        
Power-On Hours                        184.4    
Uncorrectable RAISE Errors            0        
Maximum Lifetime Temperature          61         (degree C)
SSD Life Left (PE Cycles)             100        (%)
Total Writes From Host                10960    
Total Reads To Host                   8968     
Warranty Remaining                    100        (%)

Life left                          : 100.000

Overall Health           : GOOD

The definitions are:

Item
Definition
SSD .... Slot #
PCIe slot number in server. Logical disk number assigned as cards are discovered. For example: 0-3 for card ID 1, 4-7 for card ID 2. Refer to the Sun Flash Accelerator F80 PCIe Card Product Notes for supported slots.

Related Information