Go to main content
Sun Flash Accelerator F80 PCIe Card User's Guide

Exit Print View

Updated: December 2013
 
 

Locate Card Command

The -locate command initates green blinking of the Status LED on the selected Sun Flash Accelerator F80 PCIe Card. Use this command to locate a selected card in a rack of servers. The Status LED returns to an operating status indicator after 60 seconds.

Text Menu Interface Usage: The following top-level menu lists the cards in the system and prompts you to select a card on which to perform an operation. Four Sun Flash Accelerator F80 PCIe Cards are shown in the following example:

# ddcli

ID    WarpDrive     Package Version    PCI Address
--    ---------     ---------------    -----------
1     ELP-4x200-4d-n    09.05.24.00        00:02:00:00
2     ELP-4x200-4d-n    09.05.24.00        00:03:00:00
3     ELP-4x200-4d-n    09.05.24.00        00:04:00:00
4     ELP-4x200-4d-n    09.05.24.00        00:05:00:00
Select the WarpDrive [1-4 or 0:Quit]: 1
1.    List WarpDrive Information
2.    Update Flash Package
3.    Display WarpDrive Health
4.    Locate WarpDrive
5.    Format WarpDrive
6.    Show Vital Product Data
7.    Extract SMART Logs

Select Operation [1-7 or 0:Quit]: 4
Enter Operation [1:on]:

Command Line Interface Usage: Enter the following line of text in the CLI to run the -locate command: ddcli -c 1 -locate on

Related Information