Go to main content

Oracle® SuperCluster M8 and SuperCluster M7 Zones With Oracle Database on Database Domains Configuration Guide

Exit Print View

Updated: June 2020
 
 

Determine the Available Existing Storage Capacity

You must first determine how much existing storage capacity is available before deciding how to carve that storage up for the disk groups for each cluster that you create.

The number and capacity of the drives installed in the Exadata Storage Servers vary, depending on the type of drives that are installed:

  • X7-2L Exadata Storage Server:

    • 8 x 6.4 TB Extreme Flash drives

    • 12 x 10 TB High Capacity drives

  • X6-2L Exadata Storage Server:

    • 8 x 3.2 TB Extreme Flash drives

    • 12 x 8 TB High Capacity drives

  • X5-2L Exadata Storage Server:

    • 8 x 1.6 TB Extreme Flash drives

    • 12 x 8 TB High Capacity drives

In addition, the total capacity that you have available depends on the level of redundancy that you want to set for the ASM disk groups (normal redundancy or high redundancy).

The following tables provide capacity information for the types of Exadata Storage Servers.

Table 1  X7-2L Single Storage Server Capacities
Capacity Type
8 x 6.4 TB Extreme Flash Drives
12 x 10 TB High Capacity Drives
Raw disk capacity
51.2 TB
120 TB
Usable mirrored capacity (ASM normal redundancy)
20 TB
50 TB
Usable triple mirrored capacity (ASM high redundancy)
17.2 TB
37.5 TB
Table 2  X6-2L Single Storage Server Capacities
Capacity Type
8 x 3.2 TB Extreme Flash Drives
12 x 8 TB High Capacity Drives
Raw disk capacity
25.6 TB
96 TB
Usable mirrored capacity (ASM normal redundancy)
10 TB
40 TB
Usable triple mirrored capacity (ASM high redundancy)
8.6 TB
30 TB
Table 3  X5-2L Single Storage Server Capacities
Capacity Type
8 x 1.6 TB Extreme Flash Drives
12 x 8 TB High Capacity Drives
Raw disk capacity
12.8 TB
96 TB
Usable mirrored capacity (ASM normal redundancy)
5 TB
40 TB
Usable triple mirrored capacity (ASM high redundancy)
4.3 TB
30 TB