# crsctl stop crs -f # crsctl disable crs
# zoneadm -z zonename halt
where zonename is the management host name (or Admin Name that was shown in Oracle Exadata Deployment Assistant) for this zone. For example:
# zoneadm -z scm7zdbadm02 halt
# ipmpstat -g
Output similar to the following appears. Locate the line in the output for the bondeth0 interface, highlighted in the following example output:
GROUP GROUPNAME STATE FDT INTERFACES bondmgt0 bondmgt0 ok -- net0 (net1) bondib1 bondib1 ok -- bondib1_0 (bondib1_1) bondib0 bondib0 ok -- bondib0_0 (bondib0_1) bondeth0 bondeth0 ok -- net4 (net7) stor_ipmp0 stor_ipmp0 ok -- stor_ipmp0_0 (stor_ipmp0_1)
In the example output above, those entries would be net4 and net7.
# dladm show-phys | grep ixgbe
Output similar to the following appears. Locate the lines in the output for the two entries that you noted in Step 6.b, highlighted in the following example output:
net5 Ethernet unknown 0 unknown ixgbe3 net1 Ethernet up 1000 full ixgbe1 net6 Ethernet unknown 0 unknown ixgbe4 net0 Ethernet up 1000 full ixgbe0 net4 Ethernet up 10000 full ixgbe2 net7 Ethernet up 10000 full ixgbe5
# zonecfg -z zonename zonecfg: zonename> select anet linkname=net_device#1 zonecfg: zonename:anet> set vlan-id=VLAN_ID zonecfg: zonename:anet> set lower-link=net_device#1 zonecfg: zonename:anet> end zonecfg: zonename> select anet linkname=net_device#2 zonecfg: zonename:anet> set vlan-id=VLAN_ID zonecfg: zonename:anet> set lower-link=net_device#2 zonecfg: zonename:anet> end zonecfg: zonename> verify zonecfg: zonename> commit zonecfg: zonename> exit
where:
zonename is the management host name (or Admin Name that was shown in Oracle Exadata Deployment Assistant) for this zone
VLAN_ID is a VLAN ID that you provide
net_device#1 is the first client network device that you saw in the output in Step 6.b
net_device#2 is the second client network device that you saw in the output in Step 6.b
For example:
# zonecfg -z scm7zdbadm02 zonecfg: scm7zdbadm02> select anet linkname=net4 zonecfg: scm7zdbadm02:anet> set vlan-id=13 zonecfg: scm7zdbadm02:anet> set lower-link=net4 zonecfg: scm7zdbadm02:anet> end zonecfg: scm7zdbadm02> select anet linkname=net7 zonecfg: scm7zdbadm02:anet> set vlan-id=13 zonecfg: scm7zdbadm02:anet> set lower-link=net7 zonecfg: scm7zdbadm02:anet> end zonecfg: scm7zdbadm02> verify zonecfg: scm7zdbadm02> commit zonecfg: scm7zdbadm02> exit
# zoneadm -z zonename reboot
For example:
# zoneadm -z scm7zdbadm02 reboot
# crsctl enable crs # crsctl start crs